Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Use of cell-free DNA in early detection of lung cancer: a proof-of concept study

Larissa Lee White; Mahesh Maiyani; LeeAnn M. Quintana; John David Powers; Lindsay E Nichols; Blythe Dollar; Ruth Bedoy; America Elias Martinez; Heather Spencer Feigelson (2026). Figshare

DOI 10.6084/m9.figshare.c.8397787

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Background Low-dose computed tomography (LDCT) remains the only validated modality for lung cancer screening, yet participation is suboptimal. Blood-based assays could eventually complement LDCT, but their performance for detecting early-stage disease in screening populations is uncertain. This study evaluated how well a cell-free DNA blood-based screening test can detect early-stage lung cancer in patients with LDCT screen-detected or incidental lung nodules. Methods We recruited patients via email with upcoming LDCT appointments whose results were classified under the Lung-RADS categories of 1–4. Guardant Health LUNAR® test collection kits were mailed to the participant. Participants provided a blood sample on the day of their LDCT visit, or within 30 days of the scan. Sensitivity and specificity were computed using the tumor registry as the gold standard and compared to assay results from the blood draw date closest to the date of diagnosis of cancer, but prior to receipt of any treatment. Results Of the 765 participants, 18 lung cancers were diagnosed. Most of the study population had a previous lung cancer screen. Eleven cases were diagnosed with stage 1 disease (68.8%). The sensitivity was 43.8% (95% CI:19.4–68.1%) and the specificity was 84.1% (95% CI: 81.5–86.7%), which resulted in a false positive rate of 15.9%. The negative predictive value was 98.6% and the positive predictive value was 5.6%. Exploratory stage-adjusted sensitivity was 75.4% (95% CI:63.6–87.2%). Conclusions The cfDNA assay demonstrated moderate specificity but limited sensitivity. Given the false positive rate of 15.9%, our results suggest that cfDNA-based assays for lung cancer may play a role as tools in combination with existing screening strategies pending continued validation. This proof-of-concept study is an important step in determining the feasibility of blood-based testing for early lung cancer detection.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=5; title_english_share=0.3125; title_reads=english; abstract_words=279; abstract_english_function_words=98; abstract_english_share=0.3513; abstract_reads=english; language_check=metadata_listed