Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose computed tomography: A solution for in vivo medical imaging and accurate patient-specific 3D bone modeling?

Serge Van Sint Jan; Stéphane Sobczak; Pierre-Michel Dugailly; Véronique Feipel; Philippe Lefèvre; Jean-Louis Lufimpadio; Patrick Salvia; Marco Viceconti; Marcel A. Rooze (2006). Clinical Biomechanics

DOI 10.1016/j.clinbiomech.2006.05.007

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: The number of in vivo clinical biomedical experiments based on computed tomography is increasing. International radiation-protection bodies are promoting the use of low-dose computed tomography to reduce radiation absorption by the subject undergoing imaging. On the other hand no data exist in the literature to quantify whether or not low-dose computed tomography would lead to a decrease of result quality when used for three-dimensional bone modeling and related measurements. METHODS: This paper aimed at finding a consensus between minimal X-ray radiation of the subject, and satisfactory image data quality, especially for accurate three-dimensional bone modeling. Several standard computed tomography and low-dose computed tomography sequences were analyzed in three tests and statistically compared. FINDINGS: Absence of significant difference between standard and low-dose computed sequences indicated that the low-dose setting would not produce less accurate three-dimensional models, while it decreased the effective X-ray dose up to 90% compared to standard settings. INTERPRETATION: Low-dose computed tomography seems suitable for accurate three-dimensional bone modeling, while the related effective X-ray radiation is low. Such setting is therefore advised for any in vivo medical imaging aiming to collect bone data.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=198; abstract_english_function_words=63; abstract_english_share=0.3182; abstract_reads=english; language_check=metadata_listed