Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Feasibility study of an automatic injection plan for coronary computed tomography angiography using 80 kilovolt and very low iodine dose

Y. Yang; S. Ge; Y. Chen; C.P. Jing (2025). International Journal of Radiation Research

DOI 10.61186/ijrr.23.1.135

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Background: To explore the feasibility of using various ultra-low contrast flow rates on the coronary CTA (CCTA) when the tube voltage is set at 80KV automatically on 3rdgeneration dual-source CT. Materials and Methods: A total of 180 patients with suspected coronary atherosclerotic disease were randomly divided into two groups, each subdivided into seven BMI-based subgroups (≤ 25, 25-26, 26-27, 27-28, 28-29, 29 -30, > 30).The experimental group (A) used individualized injection rates (2.8-3.4 ml/s) with 350 mg I/ml contrast agent based on BMI, with a fixed injection time of 10s.The control group (B) used a fixed injection rate of 4.0 ml/s and a fixed injection time of 12s.Both groups employed prospective ECG-gated scanning.Image quality, effective radiation dose, and contrast agent dosage were compared using the Student's t-test.Results: In Group B, the coronary artery CT value exceeded the optimal diagnostic range (300-450 HU) recommended by experts.Group A had significantly lower CT values, SNR, and CNR compared to Group B (P < 0.05), but the enhancement in Group A was closer to the optimal diagnostic range.There was no significant difference in subjective image scores between the groups (P > 0.05), with consistent scoring between two directors (ICC: 0.612-0.852).Both groups had similar effective doses (P > 0.05).The contrast agent dosage in Group A was significantly lower than in Group B (P < 0.05).Conclusion: The optimized contrast injection scheme can significantly reduce the amount of contrast agent and obtain better image quality.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=5; title_english_share=0.2632; title_reads=english; abstract_words=233; abstract_english_function_words=70; abstract_english_share=0.3004; abstract_reads=english; language_check=metadata_listed