Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Volumetric measurement of artificial pure ground-glass nodules at low-dose CT: Comparisons between hybrid iterative reconstruction and filtered back projection

Noriyuki Sakai; Hidetake Yabuuchi; Masatoshi Kondo; Tsukasa Kojima; Kazuya Nagatomo; Satoshi Kawanami; Takeshi Kamitani; Masato Yonezawa; Michinobu Nagao; Hiroshi Honda (2015). European Journal of Radiology

DOI 10.1016/j.ejrad.2015.08.018

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: To compare hybrid iterative reconstruction (HIR) with filtered back projection (FBP) in the volumetry of artificial pure ground-glass nodules (GGNs) with low-dose computed tomography (CT). MATERIALS AND METHODS: Artificial GGNs (10 mm-diameter, 523.6 mm(3), -660 HU) in an anthropomorphic chest phantom were scanned by a 256-row multi-slice CT with three dose levels (10, 30, 100 mAs). Each scan was repeated six times. Each set was reconstructed by FBP and HIR at 0.625-mm thickness. The volumes of artificial GGNs placed at the lung apex and middle lung field of the chest phantom were measured by two observers. Semi-automated measurements were performed by clicking the cursor in the center of GGNs, and manual measurements were performed by tracing GGNs on axial section. Modification of the trace was added on a sagittal or coronal section if necessary. Measurement errors were calculated for both the FBP and HIR at each dose level. We used the Wilcoxon signed rank test to identify any significant difference between the measurement errors of the FBP and HIR. Inter-observer, intra-observer, and inter-scan variabilities were evaluated by Bland Altman analysis with limits of agreements given by 95% confidence intervals. RESULTS: There were significant differences in measurement errors only at the lung apex between FBP and HIR with 10 mAs in both the semi-automated (observer 1, -37% vs. 7.2%; observer 2, -39% vs. 1.9%) and manual methods (observer 1, -29% vs. 7.5%; observer 2, -30% vs. 1.1%), respectively (P<0.05). HIR provided each variability equal to or less than one half of that of FBP at 10 mAs in both methods. In the semi-automated method, the inter-observer and intra-observer variabilities obtained by HIR at 10 mAs were -11% to 17% and -6.7% to 6.7%, whereas those for FBP at 10 mAs were -29% to 30% and -38% to 20%, respectively. The inter-scan variability for FBP at 100 mAs vs. HIR at 10 mAs was -9.5% to 11%, and that for FBP at 100 mAs vs. FBP at 10 mAs was -73% to 32%. In the manual method, the inter-observer and intra-observer variabilities for HIR at 10 mAs were -14% to 22% and -9.8% to 22%, and those for FBP at 10 mAs were -45% to 36% and -31% to 28%, respectively. The inter-scan variability for FBP at 100 mAs vs. HIR at 10 mAs was -7.4% to 23%, and that for FBP at 100 mAs vs. FBP at 10 mAs was -52% to 26%. CONCLUSION: HIR is superior to FBP in the volumetry of artificial pure GGNs at lung apex with low-dose CT.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=4; title_english_share=0.1905; title_reads=english; abstract_words=382; abstract_english_function_words=159; abstract_english_share=0.4162; abstract_reads=english; language_check=metadata_listed