Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Computed tomography-guided core needle biopsy for lung nodules: low-dose versus standard-dose protocols.

Yi-Yang Huang; Hong Cheng; Guang-Chao Li (2021). Videosurgery and Other Miniinvasive Techniques

DOI 10.5114/wiitm.2021.103303

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

INTRODUCTION: Computed tomography (CT)-guided core needle biopsy (CNB) is an essential step in the management of lung nodules (LNs). Low-dose CT (LDCT)-guided CNB has been used to decrease the radiation exposure. AIM: To evaluate the technical success, safety, diagnostic capacity, and radiation exposure to patients between LDCT-guided and standard-dose CT (SDCT)-guided CNB for LNs. MATERIAL AND METHODS: This is a retrospective, single-centre study. Patients who underwent LDCT-guided or SDCT-guided CNB for LNs from January 2015 to December 2017 were included. Data on technical success, diagnostic performance, complications, and radiation exposure were collected and analysed. RESULTS: A total of 70 and 65 patients underwent LDCT-guided and SDCT-guided CNB procedure, respectively. The technical success rates were 100% in both groups. The diagnostic yield, sensitivity, specificity, and overall diagnostic accuracy in the LDCT and SDCT groups were 71.4% and 67.7% (p = 0.637), 97.8% and 93.2% (p = 0.625), 100%, and 100%, and 98.6% and 95.4% (p = 0.560), respectively. The independent risk factor of diagnostic failure was less sample tissues (p = 0.012; 95% confidence interval: 0.033-0.651). Pneumothorax was found in 9 and 12 patients in the LDCT and SDCT groups, respectively (p = 0.369). Lung haemorrhage was found in 11 and 12 patients in the LDCT and SDCT groups, respectively (p = 0.671). The mean dose-length product was 38.3 ±17.0 mGy · cm and 376.0 ±118.7 mGy · cm in the LDCT and SDCT groups, respectively (p < 0.001). CONCLUSIONS: Compared to SDCT, LDCT-guided CNB can provide comparable safety and diagnostic performance for LNs while reducing exposure to radiation.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=15; title_english_function_words=1; title_english_share=0.0667; title_reads=not_english; abstract_words=232; abstract_english_function_words=76; abstract_english_share=0.3276; abstract_reads=english; language_check=metadata_missing