Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-Dose Lung CT Image Restoration Using Adaptive Prior Features From Full-Dose Training Database

Yuanke Zhang; Junyan Rong; Hongbing Lu; Yuxiang Xing; Jing Meng (2017). IEEE Transactions on Medical Imaging

DOI 10.1109/tmi.2017.2757035

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

The valuable structure features in full-dose computed tomography (FdCT) scans can be exploited as prior knowledge for low-dose CT (LdCT) imaging. However, lacking the capability to represent local characteristics of interested structures of the LdCT image adaptively may result in poor preservation of details/textures in LdCT image. This paper aims to explore a novel prior knowledge retrieval and representation paradigm, called adaptive prior features assisted restoration algorithm, for the purpose of better restoration of the low-dose lung CT images by capturing local features from FdCT scans adaptively. The innovation lies in the construction of an offline training database and the online patch-search scheme integrated with the principal components analysis (PCA). Specifically, the offline training database is composed of 3-D patch samples extracted from existing full-dose lung scans. For online patch-search, 3-D patches with structure similar to the noisy target patch are first selected from the database as the training samples. Then, PCA is applied on the training samples to retrieve their local prior principal features adaptively. By employing the principal features to decompose the noisy target patch and using an adaptive coefficient shrinkage technique for inverse transformation, the noise of the target patch can be efficiently removed and the detailed texture can be well preserved. The effectiveness of the proposed algorithm was validated by CT scans of patients with lung cancer. The results show that it can achieve a noticeable gain over some state-of-the-art methods in terms of noise suppression and details/textures preservation.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=1; title_english_share=0.0667; title_reads=not_english; abstract_words=254; abstract_english_function_words=90; abstract_english_share=0.3543; abstract_reads=english; language_check=metadata_listed