Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Radiomics to increase the effectiveness of lung cancer screening programs. Radiolung preliminary results.

Antoni Rosell; Sonia Baeza; Samuel García; José Luís Mate; Ignasi Guasch; Isabel Nogueira; Ignasi García-Olivé; Guillermo Torres; C. Sanchez-Ramos; Débora Gil (2022). European Respiratory Journal

DOI 10.1183/13993003.congress-2022.1498

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Introduction: Main lung cancer screening clinical trials demonstrated a 20-25% mortality reduction but rendered 19.7-27.3% false-positive nodules in the chest CT. Radiomics can provide discriminatory capacity beyond what is perceived by the naked eye. Goal: Establish a radiomic signature of pulmonary nodules (PN) to distinguish malignancy from benignity. Patients: Prospective observational study with PNs studied and resected according to usual clinical practice. Method: CT images are sent to the Computer Vision Center, and the nodules segmented. Gray Level Co-occurrence Matrix radiomic based texture features that significatively correlate with malignancy are extracted. These variables are used to train a neural network with an architecture optimized according to the diagnosis of the nodule. The model has been trained with 8 benign PNs and 43 malignant PNs from our hospital, and subsequently validated with 6 benign and 21 malignant PNs from our hospital and from a public database. Results: 51 PNs of 22.68mm (range 3-45mm), 32 men, mean age 69 years, 41 smokers or ex-smokers were analyzed. The pathological results were: 32 (62.7%) ADK, 7 (13.7%) SCC, 3 (5.8%) NSCLC, 1 (1.9%) carcinoid; 2 (3.9%) nonspecific necrosis, 6 (11.7%) benign tumors. The diagnostic accuracy of our hybrid system is 96.30%, 100% sensitivity, specificity of 83.3%. Conclusions: In our sample, the application of a hybrid radiomic system achieves high diagnostic accuracy (96.3%) to detect malignant nodules on chest CT. External validation in a lung cancer screening program is needed. Funded by: ACMCiB, BRN, Fundació Ramon Pla, Lung Ambition Alliance

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=222; abstract_english_function_words=71; abstract_english_share=0.3198; abstract_reads=english; language_check=metadata_listed