Real-time respiratory triggered SPECT myocardial perfusion imaging using CZT technology: impact of respiratory phase matching between SPECT and low-dose CT for attenuation correction
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
AIMS: To assess the impact of respiratory phase matching between single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) and low-dose computed tomography (CT) for attenuation correction (AC). METHODS AND RESULTS: Tc-tetrofosmin pharmacological stress/rest SPECT-MPI using a cadmium-zinc-telluride gamma camera. Low-dose CT for AC was performed at deep-inspiration breath-hold. SPECT-MPI was acquired once with free-breathing (FB) and repeated at deep-inspiration breath-hold (BH) to match the respiratory phase of AC. From these acquisitions we reconstructed four data sets: free-breathing SPECT-MPI without AC (non-corrected; FB-NC), breath-hold SPECT-MPI without AC (non-corrected; BH-NC), free-breathing SPECT-MPI with AC (FB-AC), and breath-hold SPECT-MPI with AC (BH-AC), the latter representing respiratory-phase-matched AC SPECT-MPI. We compared semi-quantitative segmental tracer uptake, visual diagnosis, inter-observer agreement, and image quality. Compared with FB-NC, deep-inspiration BH-NC increases inferior and lateral uptake, but decreases septal uptake. Addition of AC to FB increases inferior and septal uptake, but decreases anterolateral uptake. Combining breath-hold MPI with breath-hold CT AC (BH-AC) increases inferior, inferolateral, and septal uptake, but reduces apical uptake, without affecting anterolateral uptake, with significant differences to all other protocols. Frequency of normal scans increases across protocols: 10% with FB-NC, 21% with BH-NC, 38% with FB-AC, and 51% with BH-AC. Image quality and inter-observer agreement were highest for BH-AC among all protocols. CONCLUSION: Compared with non-corrected breath-hold SPECT-MPI and with free-breathing AC SPECT-MPI, respiratory-phase-matched AC SPECT-MPI significantly affects segmental semi-quantitative uptake, increases the frequency of normal scans, yields the best inter-observer agreement, and significantly improves image quality. These findings suggest a potential role of respiratory triggered SPECT-MPI in clinical routine.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=25; title_english_function_words=4; title_english_share=0.1600; title_reads=english; abstract_words=308; abstract_english_function_words=65; abstract_english_share=0.2110; abstract_reads=english; language_check=metadata_listed