Application of Dual-source Low-dose Computed Tomography in Lumber Examination
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Objective To evaluate the application of lower-dose scan protocol and clinical values of dual source CT(DSCT) in lumbar examination.Methods A total of 714 consecutive patients treated in our hospital between Auguest 2011 and May 2012 were orderly divided into seven groups.All participants underwent DSCT with the same tube voltage(120 kV) and care dose technology.One of seven groups was scanned with regular tube current(250 mAs),while other groups were scanned with decreasing tube current(240,230,220,210,200,and 190 mAs).All other scan parameters were identical in the whole scan process,such as collimator(64 mm×0.6 mm),recon thickness(0.75 mm),recon interval(0.7 mm), and field of view(FOV)(180-200 mm).We measured CT values and noise of centrum/myelon/erector spinae at the third and fifth lumbar level(L3/L5),and calculated the signal noise rate(SNR) of the centrum and myelon at the L3/L5 level,and the contrast noise rate(CNR) of them was compared with erector spinae.Then,we analyzed the relation between these data(SNR/CNR) acquired in different current and the index of X-ray dose,including CTDI,DLP,and ED etc.Results No difference was observed in the SNR/SD values of the centrum and myelon at the L3/L5 between group 1 and 2(P0.05).However,compared with group 3,4,5,6,and 7,there were obvious differences in the SNR values of centrum/myelon at the L3/L5 level in group 1(P0.05).With one-way ANOVA,no difference was observed in the CNR values of all groups(P0.05).Conclusions In the DSCT lumbar examinations,by means of gradually decreasing the tube current,diagnosticians can easily adapt to the lower-dose imaging,so as to make sense of the lower-dose DSCT protocol.For patients whose BMI values are less than 25 kg/m2,not only the radiation dose will be decreased with referred current(190 mAs),but also suitable imaging can be acquired to satisfy the diagnosticians.Meanwhile,it can also protect the patients from over-dose radiation and reduce facilities depletion.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=11; title_english_function_words=2; title_english_share=0.1818; title_reads=english; abstract_words=327; abstract_english_function_words=126; abstract_english_share=0.3853; abstract_reads=english; language_check=metadata_listed