Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

SOS study: Lung cancer detection with chest digital tomosynthesis

Luca Bertolaccini; Andrea Viti; Maurizio Grosso; Alberto Claudio Terzi (2014). European Respiratory Journal

DOI 10.1183/13993003/erj.44.suppl_58.1918

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND. In Low-Dose CT (LDCT) screening programs for Lung Cancer (LC), radiation exposure and costs are still problems. SOS study was single-arm observational study of chest Digital Tomosynthesis (DT) for LC-detection in an at-risk population. DT is limited angle tomography that allows reconstruction of multiple image planes and provides high-resolution images in coronal planes. METHODS. Accrual of study participants started in December 2010, ended in December 2011. Eligible: smokers or former smokers (45-75 years), smoking history ≥20 pack-years, without malignancy in 5 years before. DT was performed at baseline and another the following year. In subjects with uncertain nodule >5 mm or multiple nodules, first-line LDCT was warranted. RESULTS. Of 1919 candidates assessed, 1843 (96%) were enrolled into study (77% currently smokers). 1843 baseline DT were obtained. Pulmonary abnormalities were detected in 14.5% subjects. First-line LDCT was carried out in 7.2%. LC was detected in 18 (0.98%). 1,703 (92% of baseline, drop out=0.4%) first round DT were obtained. New lung nodules >5 mm were detected in 13 (0.7%). LC was diagnosed in 5 subjects with First Round LC detection rate 0.3%. Overall LC detection rate was 1.25%. Tumor stage and histology in subjects with LC diagnosed by chest DT No. of subjects TUMOR STAGE Baseline First Round IA 6 4 IB 2 IIA 2 1 IIB 1 IIIA 1 IIIB 1 IV 5 HISTOLOGY Baseline First Round Adenocarcinoma 10 1 Squamous cell carcinoma 7 4 Carcinoid 1 CONCLUSIONS. LC detection rate was comparable to LDCT (0.98%) with low effective radiation dose (0.13 mSv), and 1/6 cost. DT is possible first-line LC screening tool and is effective in high-risk subjects follow-up.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=1; title_english_share=0.1111; title_reads=english; abstract_words=241; abstract_english_function_words=62; abstract_english_share=0.2573; abstract_reads=english; language_check=metadata_listed