Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Optimum diameter threshold for lung nodules at baseline lung cancer screening with low-dose chest CT: exploration of results from the Korean Lung Cancer Screening Project

Eui Jin Hwang; Jin Mo Goo; Hyae Young Kim; Jaeyoun Yi; Yeol Kim (2021). European Radiology

DOI 10.1007/s00330-021-07827-8

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVES: To explore the optimum diameter threshold for solid nodules to define positive results at baseline screening low-dose CT (LDCT) and to compare two-dimensional and volumetric measurement of lung nodules for the diagnosis of lung cancers. METHODS: We included consecutive participants from the Korean Lung Cancer Screening project between 2017 and 2018. The average transverse diameter and effective diameter (diameter of a sphere with the same volume) of lung nodules were measured by semi-automated segmentation. Diagnostic performances for lung cancers diagnosed within 1 year after LDCT were evaluated using area under receiver-operating characteristic curves (AUCs), sensitivities, and specificities, with diameter thresholds for solid nodules ranging from 6 to 10 mm. The reduction of unnecessary follow-up LDCTs and the diagnostic delay of lung cancers were estimated for each threshold. RESULTS: Fifty-two lung cancers were diagnosed among 10,424 (10,141 men; median age 62 years) participants within 1 year after LDCT. Average transverse (0.980) and effective diameters (0.981) showed similar AUCs (p = .739). Elevating the average transverse diameter threshold from 6 to 9 mm resulted in a significantly increased specificity (91.7 to 96.7%, p < .001), a modest reduction in sensitivity (96.2 to 94.2%, p = .317), a 60.2% estimated reduction of unnecessary follow-up LDCTs, and a diagnostic delay in 1.9% of lung cancers. Elevating the threshold to 10 mm led to a significant reduction in sensitivity (86.5%, p = .025). CONCLUSIONS: Elevating the diameter threshold for solid nodules from 6 to 9 mm may lead to a substantial reduction in unnecessary follow-up LDCTs with a small proportion of diagnostic delay of lung cancers. KEY POINTS: • Elevation of the diameter threshold for solid nodules from 6 to 9 mm can substantially reduce unnecessary follow-up LDCTs with a small proportion of diagnostic delay of lung cancers. • The average transverse and effective diameters of lung nodules showed similar performances for the prediction of a lung cancer diagnosis.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=26; title_english_function_words=6; title_english_share=0.2308; title_reads=english; abstract_words=289; abstract_english_function_words=97; abstract_english_share=0.3356; abstract_reads=english; language_check=metadata_listed