Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Development of deep learning-assisted overscan decision algorithm in low-dose chest CT: Application to lung cancer screening in Korean National CT accreditation program
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
We propose a deep learning-assisted overscan decision algorithm in chest low-dose computed tomography (LDCT) applicable to the lung cancer screening. The algorithm reflects the radiologists' subjective evaluation criteria according to the Korea institute for accreditation of medical imaging (KIAMI) guidelines, where it judges whether a scan range is beyond landmarks' criterion. The algorithm consists of three stages: deep learning-based landmark segmentation, rule-based logical operations, and overscan determination. A total of 210 cases from a single institution (internal data) and 50 cases from 47 institutions (external data) were utilized for performance evaluation. Area under the receiver operating characteristic (AUROC), accuracy, sensitivity, specificity, and Cohen's kappa were used as evaluation metrics. Fisher's exact test was performed to present statistical significance for the overscan detectability, and univariate logistic regression analyses were performed for validation. Furthermore, an excessive effective dose was estimated by employing the amount of overscan and the absorbed dose to effective dose conversion factor. The algorithm presented AUROC values of 0.976 (95% confidence interval [CI]: 0.925-0.987) and 0.997 (95% CI: 0.800-0.999) for internal and external dataset, respectively. All metrics showed average performance scores greater than 90% in each evaluation dataset. The AI-assisted overscan decision and the radiologist's manual evaluation showed a statistically significance showing a p-value less than 0.001 in Fisher's exact test. In the logistic regression analysis, demographics (age and sex), data source, CT vendor, and slice thickness showed no statistical significance on the algorithm (each p-value > 0.05). Furthermore, the estimated excessive effective doses were 0.02 ± 0.01 mSv and 0.03 ± 0.05 mSv for each dataset, not a concern within slight deviations from an acceptable scan range. We hope that our proposed overscan decision algorithm enables the retrospective scan range monitoring in LDCT for lung cancer screening program, and follows an as low as reasonably achievable (ALARA) principle.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=24; title_english_function_words=4; title_english_share=0.1667; title_reads=english; abstract_words=292; abstract_english_function_words=89; abstract_english_share=0.3048; abstract_reads=english; language_check=metadata_listed