Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low dose contrast CT for transcatheter aortic valve replacement assessment: Results from the prospective SPECTACULAR study (spectral CT assessment prior to TAVR)

Armando Ugo Cavallo; Andrew J. Patterson; Rahul Thomas; Mohamad Amer Alaiti; Guilherme F. Attizzani; Kai Laukamp; Nils Große Hokamp; Hiram Bezerra; Robert Gilkeson; Sanjay Rajagopalan (2020). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2019.06.015

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: Computed tomographic angiography (CTA) based planning for transcatheter aortic valve replacement (TAVR) is essential for reduction of periprocedural complications. Spectral CT based imaging provides several advantages, including better contrast/signal to noise ratio and increased soft tissue contrast, permitting better delineation of contrast filled structures at lower doses of iodinated contrast media. The aim of this prospective study was to assess the initial feasibility of a low dose iodinated contrast protocol, utilizing monoenergetic 40 keV reconstruction, using a dual-layer CT scanner (DLCT) for CTA in patients undergoing TAVR planning. METHODS: 116 consecutive TAVR patients underwent a gated chest and a non-gated CTA of the abdomen and pelvis. 40 keV virtual monoenergetic images (VMI) were reconstructed and compared with conventional polychromatic images (CI). The proximal aorta and access vessels were scored for image quality by independent experienced cardiovascular imagers. RESULTS: Proximal aortic image quality as assessed by signal to noise (SNR) and contrast to noise ratio (CNR), were significantly better with 40 keV VMI relative to CI (SNR 14.65 ± 7.37 vs 44.16 ± 22.39, p < 0.001; CNR 15.84 ± 9.93 vs 59.8 ± 40.83, p < 0.001). Aortic root dimensions were comparable between the two approaches with a bias towards higher measurements at 40 keV (Bland Altman). SNR and CNR in all access vessel segments at 40 keV were substantially better (p < 0.001 for all peripheral access vessel segments) with comparable image quality. CONCLUSION: 40 keV VMI with low dose contrast dose spectral imaging is feasible for comprehensive preprocedural evaluation of access vessels and measurements of aortic root dimensions in patients undergoing TAVR.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=22; title_english_function_words=4; title_english_share=0.1818; title_reads=english; abstract_words=243; abstract_english_function_words=65; abstract_english_share=0.2675; abstract_reads=english; language_check=metadata_listed