Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A Comparison of the Image Quality and Radiation Dose With Routine Computed Tomography and the Latest Gemstone Spectral Imaging Combination of Different Scanning Protocols in Computed Tomography Angiography of the Kidney

Yong-Xia Zhao; Hong-Na Suo; Zi-Wei Zuo; Ying-jin Xu; Jin Chang (2017). Journal of Computer Assisted Tomography

DOI 10.1097/rct.0000000000000510

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

OBJECTIVE: The objective of our study was to compare the image quality and radiation dose of computed tomography angiography (CTA) of the kidney in patients with different body mass indexes using routine CT and the latest gemstone spectral imaging (GSI) combination of different scanning protocols with the adaptive statistical iterative reconstruction 2.0 algorithm. METHODS: A total of 90 patients who had undergone a CTA of the kidney were divided into 3 groups (A, B, and C), with 30 patients in each group. Group A underwent a routine CT examination, whereas groups B and C underwent GSI with different scanning protocols. All images were restructured using the adaptive statistical iterative reconstruction 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated when the kidney CTA was completed. Each subjective image evaluation used a 5-point scoring method and was conducted by 2 independent radiologists. The CT dose index of volume and the dose-length product were recorded, and the mean value was calculated. The dose-length product was converted to the effective dose. All data were compared with a 1-way analysis of variance. RESULTS: The SNR, CNR, and subjective image quality in group A were significantly lower than those in groups B and C (P < 0.01). There were no significant differences in SNR, CNR, and subjective image quality between groups B and C. The effective dose of group C decreased by 46.05% and 15.03% relative to those of groups A and B, respectively (P < 0.01). CONCLUSIONS: The latest GSI with different scanning protocols can more effectively reduce the radiation dose than can the routine CT scan mode for a kidney CTA while still maintaining diagnostic image quality.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=31; title_english_function_words=11; title_english_share=0.3548; title_reads=english; abstract_words=273; abstract_english_function_words=106; abstract_english_share=0.3883; abstract_reads=english; language_check=metadata_listed