Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Evaluating Explainability in Transfer Learning Models for Pulmonary Nodules Classification: A Comparative Analysis of Generalizability and Interpretability

Amira Bouamrane; Makhlouf Derdour; Ahmed Alksas; Ayman S El-Baz (2025). International Journal of Pattern Recognition and Artificial Intelligence

DOI 10.1142/s0218001425400014

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Computerized diagnostic systems have come a long way in terms of providing credible and speedy results in the diagnosis of lung cancer, which has become one of the leading causes of death worldwide in recent years. This progress is particularly true with the advancements in models based on deep convolutional neural networks (CNNs) using computed tomography (CT) images. However, the decision-making processes of such models are less than exactly interpretable, as they are considered black boxes. This makes physicians reluctant to trust and use them.The aim of this paper is to compare several transfer models that were pre-trained on the ImageNet dataset and apply them to lung cancer diagnosis, evaluating their generalizability and robustness. This comparative study implements a number of models including MobileNetV2, EfficientNetV2-L, EfficientNet-B7, DenseNet201, VGG19, VGG16, ResNet50, Xception, NasNetLarge, and InceptionV3. The models were trained on four distinct datasets to evaluate data diversity and heterogeneity. The models’ generalization capabilities were assessed using two separate datasets: IQ-OTH/NCCD and the LDCT dataset. To enhance the models explainability and trustworthiness, the Local Interpretable Model-Agnostic Explanations (LIME) method was utilized. Among the tested models, MobileNetV2 and ResNet50 demonstrated the highest performance and stability. MobileNetV2 achieved an accuracy of 99.28%, with false positive and false negative rates of 1.23% and 0%, respectively. ResNet50 achieved an accuracy of 99.38%, with false positive and false negative rates of 0% and 1.23%, respectively.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=5; title_english_share=0.2941; title_reads=english; abstract_words=230; abstract_english_function_words=83; abstract_english_share=0.3609; abstract_reads=english; language_check=metadata_listed