Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Variability in interpretation of low-dose chest CT using computerized assessment in a nationwide lung cancer screening program: comparison of prospective reading at individual institutions and retrospective central reading

Eui Jin Hwang; Jin Mo Goo; Hyae Young Kim; Soon Ho Yoon; Gong Yong Jin; Jaeyoun Yi; Yeol Kim (2020). European Radiology

DOI 10.1007/s00330-020-07424-1

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVES: To evaluate the degree of variability in computer-assisted interpretation of low-dose chest CTs (LDCTs) among radiologists in a nationwide lung cancer screening (LCS) program, through comparison with a retrospective interpretation from a central laboratory. MATERIALS AND METHODS: Consecutive baseline LDCTs (n = 3353) from a nationwide LCS program were investigated. In the institutional reading, 20 radiologists in 14 institutions interpreted LDCTs using computer-aided detection and semi-automated segmentation systems for lung nodules. In the retrospective central review, a single radiologist re-interpreted all LDCTs using the same system, recording any non-calcified nodules ≥ 3 mm without arbitrary rejection of semi-automated segmentation to minimize the intervention of radiologist's discretion. Positive results (requiring additional follow-up LDCTs or diagnostic procedures) were initially classified by the lung CT screening reporting and data system (Lung-RADS) during the interpretation, while the classifications based on the volumetric criteria from the Dutch-Belgian lung cancer screening trial (NELSON) were retrospectively applied. Variabilities in positive rates were assessed with coefficients of variation (CVs). RESULTS: In the institutional reading, positive rates by the Lung-RADS ranged from 7.5 to 43.3%, and those by the NELSON ranged from 11.4 to 45.0% across radiologists. The central review exhibited higher positive rates by Lung-RADS (20.0% vs. 27.3%; p < .001) and the NELSON (23.1% vs. 37.0%; p < .001), and lower inter-institution variability (CV, 0.30 vs. 0.12, p = .003 by Lung-RADS; CV, 0.25 vs. 0.12, p = .014 by the NELSON) compared to the institutional reading. CONCLUSION: Considerable inter-institution variability in the interpretation of LCS results is caused by different usage of the computer-assisted system. KEY POINTS: • Considerable variability existed in the interpretation of screening LDCT among radiologists partly from the different usage of the computerized system. • A retrospective reading of low-dose chest CTs in the central laboratory resulted in reduced variability but an increased positive rate.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=29; title_english_function_words=7; title_english_share=0.2414; title_reads=english; abstract_words=294; abstract_english_function_words=96; abstract_english_share=0.3265; abstract_reads=english; language_check=metadata_listed