Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Hybrid plug-and-play CT image restoration using nonconvex low-rank group sparsity and deep denoiser priors

Chunyan Liu; Sui Li; Dianlin Hu; Yuxiang Zhong; Jianjun Wang; Peng Zhang (2024). Physics in Medicine and Biology

DOI 10.1088/1361-6560/ad8c98

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Objective. Low-dose computed tomography (LDCT) is an imaging technique that can effectively help patients reduce radiation dose, which has attracted increasing interest from researchers in the field of medical imaging. Nevertheless, LDCT imaging is often affected by a large amount of noise, making it difficult to clearly display subtle abnormalities or lesions. Therefore, this paper proposes a multiple complementary priors CT image reconstruction method by simultaneously considering both the internal prior and external image information of CT images, thereby enhancing the reconstruction quality of CT images. Approach. Specifically, we propose a CT image reconstruction method based on weighted nonconvex low-rank regularized group sparse and deep image priors under hybrid plug-and-play framework by utilizing the weighted nonconvex low rankness and group sparsity of dictionary domain coefficients of each group of similar patches, and a convolutional neural network denoiser. To make the proposed reconstruction problem easier to tackle, we utilize the alternate direction method of multipliers for optimization. Main results. To verify the performance of the proposed method, we conduct detailed simulation experiments on the images of the abdominal, pelvic, and thoracic at projection views of 45, 65, and 85, and at noise levels of 1 × 10 5 and 1 × 10 6 , respectively. A large number of qualitative and quantitative experimental results indicate that the proposed method has achieved better results in texture preservation and noise suppression compared to several existing iterative reconstruction methods. Significance. The proposed method fully considers the internal nonlocal low rankness and sparsity, as well as the external local information of CT images, providing a more effective solution for CT image reconstruction. Consequently, this method enables doctors to diagnose and treat diseases more accurately by reconstructing high-quality CT images.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=2; title_english_share=0.1176; title_reads=english; abstract_words=278; abstract_english_function_words=88; abstract_english_share=0.3165; abstract_reads=english; language_check=metadata_listed