Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Two-phase (low-dose) computed tomography is as effective as 4D-CT for identifying enlarged parathyroid glands
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref, OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: Four-dimensional computed tomography (4D-CT) is often used for patients with primary hyperparathyroidism and non-definitive localization after Sestamibi scan (MIBI) and ultrasound (US), but may expose patients to unnecessary radiation, typically between 10 and 26 millisieverts (mSv). We hypothesize that a simpler two-phase CT protocol would have a similar sensitivity, specificity and accuracy to those published for 4D-CT, while exposing the patient to less radiation. METHODS: We reviewed 54 patients with primary hyperparathyroidism and non-definitive localization studies who had a two-phase CT between 2009 and 2012 at our tertiary referral center. RESULTS: The mean radiation dose of two-phase CT over the course of the study was 5.2 mSv (range 3.5 mSv-9.1 mSv). Two-phase CT had a 77% (CI = 65%-86%) sensitivity and an 87% (CI = 73%-95%) specificity to lateralize enlarged parathyroid glands to the correct side of the neck and a 58% (CI = 45%-68%) sensitivity and 91% (CI = 83%-94%) specificity to localize parathyroid tumors to the correct quadrant of the neck. The overall accuracy of two-phase CT to lateralize enlarged parathyroids was 81% (CI = 73%, 88%) and the accuracy to localize enlarged parathyroids was 79% (CI = 73%, 84%). DISCUSSION: As a second line investigation two-phase CT has a similar sensitivity, specificity and accuracy to those published for 4D-CT in patients with non-localized, enlarged parathyroids with less radiation exposure. Two-phase CT can help localize enlarged parathyroid glands not definitively identified using MIBI and US. CONCLUSION: Two-phase CT allows clinicians to accurately identify enlarged parathyroid glands while exposing the patient to less radiation than 4D-CT.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=17; title_english_function_words=4; title_english_share=0.2353; title_reads=english; abstract_words=247; abstract_english_function_words=83; abstract_english_share=0.3360; abstract_reads=english; language_check=metadata_listed