Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Radiation Dose Reduction in Computed Tomography-Guided Lung Interventions using an Iterative Reconstruction Technique

De‐Hua Chang; S. Hiss; Dirk Müeller; Martin Hellmich; Jan Borggrefe; Alexander Christian Bunck; David C. Maintz; M. Hackenbroch (2015). RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren

DOI 10.1055/s-0035-1553125

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: To compare the radiation doses and image qualities of computed tomography (CT)-guided interventions using a standard-dose CT (SDCT) protocol with filtered back projection and a low-dose CT (LDCT) protocol with both filtered back projection and iterative reconstruction. MATERIALS AND METHODS: Image quality and radiation doses (dose-length product and CT dose index) were retrospectively reviewed for 130 patients who underwent CT-guided lung interventions. SDCT at 120 kVp and automatic mA modulation and LDCT at 100 kVp and a fixed exposure were each performed for 65 patients. Image quality was objectively evaluated as the contrast-to-noise ratio and subjectively by two radiologists for noise impression, sharpness, artifacts and diagnostic acceptability on a four-point scale. RESULTS: The groups did not significantly differ in terms of diagnostic acceptability and complication rate. LDCT yielded a median 68.6% reduction in the radiation dose relative to SDCT. In the LDCT group, iterative reconstruction was superior to filtered back projection in terms of noise reduction and subjective image quality. The groups did not differ in terms of beam hardening artifacts. CONCLUSION: LDCT was feasible for all procedures and yielded a more than two-thirds reduction in radiation exposure while maintaining overall diagnostic acceptability, safety and precision. The iterative reconstruction algorithm is preferable according to the objective and subjective image quality analyses. KEY POINTS: Implementation of a low-dose computed tomography (LDCT) protocol for lung interventions is feasible and safe. LDCT protocols yield a significant reduction (more than 2/3) in radiation exposure. Iterative reconstruction algorithms considerably improve the image quality in LDCT protocols.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=de; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=256; abstract_english_function_words=84; abstract_english_share=0.3281; abstract_reads=english; language_check=both_english