Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Improving spatial resolution with an edge-enhancement model for low-dose propagation-based X-ray phase-contrast computed tomography

Lin Zhang; Huijuan Zhao; Zhongxing Zhou; Mengyu Jia; Limin Zhang; Jingying Jiang; Feng Gao (2021). Optics Express

DOI 10.1364/oe.440664

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Propagation-based X-ray phase-contrast computed tomography (PB-PCCT) has been increasingly popular for distinguishing low contrast tissues. Phase retrieval is an important step to quantitatively obtain the phase information before the tomographic reconstructions, while typical phase retrieval methods in PB-PCCT, such as homogenous transport of intensity equation (TIE-Hom), are essentially low-pass filters and thus improve the signal to noise ratio at the expense of the reduced spatial resolution of the reconstructed image. To improve the reconstructed spatial resolution, measured phase contrast projections with high edge enhancement and the phase projections retrieved by TIE-Hom were weighted summed and fed into an iterative tomographic algorithm within the framework of the adaptive steepest descent projections onto convex sets (ASD-POCS), which was employed for suppressing the image noise in low dose reconstructions because of the sparse-view scanning strategy or low exposure time for single phase contrast projection. The merging strategy decreases the accuracy of the linear model of PB-PCCT and would finally lead to the reconstruction failure in iterative reconstructions. Therefore, the additive median root prior is also introduced in the algorithm to partly increase the model accuracy. The reconstructed spatial resolution and noise performance can be flexibly balanced by a pair of antagonistic hyper-parameters. Validations were performed by the established phase-contrast Feldkamp-Davis-Kress, phase-retrieved Feldkamp-Davis-Kress, conventional ASD-POCS and the proposed enhanced ASD-POCS with a numerical phantom dataset and experimental biomaterial dataset. Simulation results show that the proposed algorithm outperforms the conventional ASD-POCS in spatial evaluation assessments such as root mean square error (a ratio of 9.78%), contrast to noise ratio (CNR) (a ratio of 7.46%), and also frequency evaluation assessments such as modulation transfer function (a ratio of 66.48% of MTF50% (50% MTF value)), noise power spectrum (a ratio of 35.25% of f50% (50% value of the Nyquist frequency)) and noise equivalent quanta (1-2 orders of magnitude at high frequencies). Experimental results again confirm the superiority of proposed strategy relative to the conventional one in terms of edge sharpness and CNR (an average increase of 67.35%).

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=3; title_english_share=0.1579; title_reads=english; abstract_words=343; abstract_english_function_words=118; abstract_english_share=0.3440; abstract_reads=english; language_check=metadata_listed