Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Defining the Intra-subject Variability of Whole-lung CT Densitometry in Two Lung Cancer Screening Trials

Stefano Diciotti; Nicola Sverzellati; Hans‐Ulrich Kauczor; Simone Lombardo; Massimo Falchini; Giuditta Favilli; Letizia Macconi; Jan‐Martin Kuhnigk; Alfonso Vittorio Marchianò; Ugo Pastorino; Maurizio Zompatori; Mario Mascalchi (2011). Academic Radiology

DOI 10.1016/j.acra.2011.08.001

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

RATIONALE AND OBJECTIVES: To define a statistically based variation of individual whole-lung densitometry above which a real increase of pulmonary extent can be suspected in lung cancer screening trials. MATERIALS AND METHODS: Baseline and 3-month follow-up low-dose computed tomography (LDCT) examinations of 131 smokers or former smokers recruited in the ITALUNG (32 subjects) and MILD (99 subjects) trials were compared using for each data set two different image processing tools for whole-lung densitometry. Both trials were approved by institutional review boards, and written informed consent was obtained from all participants. Assuming that no change of emphysema extent can occur in a 3-month interval, the Bland and Altman method was used to assess the agreement between baseline and follow-up LDCT examinations for lung volume, 15th percentile (Perc15) of lung density and Perc15 corrected for lung volume by application of a linear detrend on log-transformed data. RESULTS: Similar results were obtained in each data set using two different image processing tools. In the ITALUNG cohort the 95% limits of agreement (LoA) interval of volume corrected Perc15 was -9.7 to 10.7% using image processing method 1 and -10.3 to 11.5% using image processing method 2. In the MILD cohort, the 95% LoA interval of volume corrected Perc15 was -14.7 to 17.3% with both image processing methods. CONCLUSION: In the two considered lung cancer screening settings a range of 9.7-14.7% decrease of volume corrected Perc15 represents a statistically defined threshold to suspect a real increase of emphysema extent in serial LDCT examinations.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=3; title_english_share=0.1875; title_reads=english; abstract_words=240; abstract_english_function_words=79; abstract_english_share=0.3292; abstract_reads=english; language_check=metadata_listed