Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Lung Nodule Malignancy Prediction in Sequential CT Scans: Summary of ISBI 2018 Challenge

Yoganand Balagurunathan; Andrew L. Beers; Michael F. McNitt‐Gray; Lubomir M. Hadjiiski; Sandy A. Napel; Dmitry B. Goldgof; Gustavo Perez; Pablo Arbeláez; Alireza Mehrtash; Tina Kapur; Ehwa Yang; Jung Won Moon; Gabriel Bernardino; Ricard Delgado-Gonzalo; Mohammad Mehdi Farhangi; Amir A. Amini; Renkun Ni; Xue Feng; Aditya Bagari; Kiran Vaidhya; Benjamin P. Veasey; Wiem Safta; Hichem Frigui; Joseph Enguehard; Ali Gholipour; Laura Silvana Castillo; Laura Alexandra Daza; Paul F. Pinsky; Jayashree Kalpathy–Cramer; Keyvan Farahani (2021). IEEE Transactions on Medical Imaging

DOI 10.1109/tmi.2021.3097665

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Lung cancer is by far the leading cause of cancer death in the US. Recent studies have demonstrated the effectiveness of screening using low dose CT (LDCT) in reducing lung cancer related mortality. While lung nodules are detected with a high rate of sensitivity, this exam has a low specificity rate and it is still difficult to separate benign and malignant lesions. The ISBI 2018 Lung Nodule Malignancy Prediction Challenge, developed by a team from the Quantitative Imaging Network of the National Cancer Institute, was focused on the prediction of lung nodule malignancy from two sequential LDCT screening exams using automated (non-manual) algorithms. We curated a cohort of 100 subjects who participated in the National Lung Screening Trial and had established pathological diagnoses. Data from 30 subjects were randomly selected for training and the remaining was used for testing. Participants were evaluated based on the area under the receiver operating characteristic curve (AUC) of nodule-wise malignancy scores generated by their algorithms on the test set. The challenge had 17 participants, with 11 teams submitting reports with method description, mandated by the challenge rules. Participants used quantitative methods, resulting in a reporting test AUC ranging from 0.698 to 0.913. The top five contestants used deep learning approaches, reporting an AUC between 0.87 - 0.91. The team's predictor did not achieve significant differences from each other nor from a volume change estimate (p =.05 with Bonferroni-Holm's correction).

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=229; abstract_english_function_words=82; abstract_english_share=0.3581; abstract_reads=english; language_check=metadata_listed