Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Temporal subtraction of low-dose and relatively thick-slice CT images with large deformation diffeomorphic metric mapping and adaptive voxel matching for detection of bone metastases: A STARD-compliant article

充輝 土屋 (2020). Institutional Repositories DataBase (IRDB)

Source record

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

To evaluate the improvement of radiologist performance in detecting bone metastases at follow up low-dose computed tomography (CT) by using a temporal subtraction (TS) technique based on an advanced nonrigid image registration algorithm. Twelve patients with bone metastases (males, 5; females, 7; mean age, 64.8±7.6 years; range 51?81 years) and 12 control patients without bone metastases (males, 5; females, 7; mean age, 64.8±7.6 years; 51?81 years) were included, who underwent initial and follow-up CT examinations between December 2005 and July 2016. Initial CT images were registered to follow-up CT images by the algorithm, and TS images were created. Three radiologists independently assessed the bone metastases with and without the TS images. The reader averaged jackknife alternative free-response receiver operating characteristics figure of merit was used to compare the diagnostic accuracy. The reader-averaged values of the jackknife alternative free-response receiver operating characteristics figures of merit (θ) significantly improved from 0.687 for the readout without TS and 0.803 for the readout with TS (P value=.031. F statistic=5.24). The changes in the absolute value of CT attenuations in true-positive lesions were significantly larger than those in false-negative lesions (P<.001). Using TS, segment-based sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the readout with TS were 66.7%, 98.9%, 94.4%, 90.9%, and 94.8%, respectively. The TS images can significantly improve the radiologist’s performance in the detection of bone metastases on low-dose and relatively thick-slice CT.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=30; title_english_function_words=7; title_english_share=0.2333; title_reads=english; abstract_words=227; abstract_english_function_words=68; abstract_english_share=0.2996; abstract_reads=english; language_check=metadata_listed