Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Histogram-Based Densitometry Index to Assess the Severity of Interstitial Lung Disease in Systemic Sclerosis in Standard and Low-Dose Computed Tomography

Cosimo Bruni; Lorenzo Tofani; Alexandru Garaiman; Suzana Jordan; Carmen-Marina Mihai; Rucsandra Dobrota; Muriel Elhaï; Mike Oliver Becker; Anna‐Maria Hoffmann‐Vold; Thomas Frauenfelder; Marco Matucci‐Cerinic; Oliver Distler (2024). The Journal of Rheumatology

DOI 10.3899/jrheum.2023-0415

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Objective Mean lung attenuation, skewness, and kurtosis are histogram-based densitometry variables that quantify systemic sclerosis–associated interstitial lung disease (SSc-ILD) and were recently merged into a computerized integrated index (CII). Our work tested the CII in low-dose 9-slice (reduced) and standard high-resolution computed tomography (CT) scans to evaluate extensive SSc-ILD and predict mortality. Methods CT scans from patients with SSc-ILD were assessed using the software Horos to compute standard and reduced CIIs. Extensive ILD was determined following the Goh staging system. The association between CIIs and extensive ILD was analyzed with a generalized estimating equation regression model, the predictive ability of CIIs by the area under the receiver-operation characteristic curve (AUC), and the association between CIIs and death by Kaplan-Meier analysis. Results Among 243 patients with standard and reduced CT scans available, 157 CT scans from 119 patients with SSc-ILD constituted the derivation cohort. The validation cohort included 116 standard and 175 reduced CT scans. Both CIIs from standard (odds ratio [OR] 0.53, 95% CI 0.37-0.75; AUC 0.77, 95% CI 0.68-0.87) and reduced CT scans (OR 0.54, 95% CI 0.35-0.82; AUC 0.78, 95% CI 0.70-0.87) were significantly associated with extensive ILD. A threshold of CII ≤ −0.96 for standard CT scans and CII ≤ −1.85 for reduced CT scans detected extensive ILD with high sensitivity in both derivation and validation cohorts. Extensive ILD according to Goh staging (OR 2.94, 95% CI 1.10-7.82) and standard CII ≤ −0.96 (OR 1.78, 95% CI 1.24-2.56) significantly predicted mortality; a marginalPvalue was observed for reduced CII ≤ −1.85 (OR 1.27, 95% CI 0.93-1.75). Conclusion Thresholds for both standard and reduced CII to identify extensive ILD were developed and validated, with an additional association with mortality. CIIs might help in clinical practice when radiology expertise is missing.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=22; title_english_function_words=6; title_english_share=0.2727; title_reads=english; abstract_words=267; abstract_english_function_words=83; abstract_english_share=0.3109; abstract_reads=english; language_check=metadata_listed