Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Application of MRI in Lung Cancer Screening: An Initial Case Series Evaluation

K. Dollar; W. Chua; Ching-Yang Wu; C. Gregorio; D. Gregory; E. Gholian; Patricia A. Thompson; C. Lee; Debiao Li; Yibin Xie; Sara Ghandehari (2025). American Journal of Respiratory and Critical Care Medicine

DOI 10.1164/ajrccm.2025.211.abstracts.a4797

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Rationale: Lung cancer screening (LCS) with low dose computed tomography (LDCT) can be challenging given the exposure to radiation. The American College of Radiology reports procedures using ionizing radiation and thus radiation exposure have significantly increased over a patient's lifetime. MRI presents an option to undergo LCS without radiation exposure. Recent meta-analysis of European and Asian literature has shown comparable sensitivity and specificity using MRI for lung nodule detection and characterization relative to LDCT. There is little literature from the US regarding the use of MRI in LCS as well as the patient's perspective on MRI as an acceptable option for LCS. Methods: This case series analyzes four participants who were found to have lung nodules on a low-dose computed tomography (LDCT) while undergoing lung cancer screening, followed by MRI imaging within six weeks of the LDCT date. These participants are part of a prospective feasibility study. To be included in the study the minimal nodule size must be 6 mm in diameter on LDCT. The MRI included 3 main sequences: diffusion weighted imaging (DWI), Dixon method, and volumetric interpolated breath-hold examination using spiral trajectory (Spiral VIBE). Each MRI was prospectively analyzed and compared to the corresponding LDCT to assess nodule visibility. After completing MRI scans, each participant filled out an MRI feasibility questionnaire. Results: All visible nodules on CT were seen on MRI. One participant had multiple nodules. The median nodule size is 11mm by 6.5mm. One nodule was subsolid with the remainder being solid. These nodules, with the exception of one, were best visualized with the Spiral VIBE sequence. The patients were either neutral or accepting of MRI as an imaging modality for LCS. Conclusion: This study supports the possible application of MRI for use to detect lung nodules in LCS. This small subset of patients was not opposed to undergoing MRI for LCS.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=3; title_english_share=0.2500; title_reads=english; abstract_words=310; abstract_english_function_words=111; abstract_english_share=0.3581; abstract_reads=english; language_check=metadata_listed