Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

TAPNet: A Geometry-Aware Triaxial Projection Network for Efficient Volumetric Pulmonary Nodule Detection

Sitong Yan; Yasheng Chang (2026). International Joint Conference on Neural Networks (IJCNN)

DOI 10.1109/ijcnn69854.2026.11729043

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Early and reliable pulmonary nodule detection from low-dose CT (LDCT) is crucial for reducing lung-cancer mortality, yet computer-aided detection remains constrained by the cubic cost of dense 3D convolution and the limited context of purely 2D pipelines. We propose TAPNet, a geometry-aware end-to-end detector that converts volumetric feature tensors into three orthogonal projections (axial/coronal/sagittal), exploits the isotropic appearance consistency of nodules across views, and suppresses anisotropic distractors such as vessels and pleural thickening. TAPNet introduces (i) a Triaxial Projection Aggregation (TAP) operator that collapses one spatial axis to enable lightweight 2D processing within a 3D encoder–decoder detector, and (ii) an Interaction-Enhanced (IE) cross-view fusion module that performs view-to-view consistency checking before writing refined features back into the 3D stream. A localized triaxial verification head further re-scores top proposals to reduce false positives at clinically relevant operating points. On LIDC-IDRI under the official LUNA16 fully automated detection protocol, TAPNet achieves 57.02% CPM with statistically tight confidence intervals and improves sensitivity in the low FP/scan regime (1–2 FP/scan) while adding only millisecond-level overhead. Extensive ablations, robustness analyses across nodule types and acquisition settings, and an efficiency study support the proposed design.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=2; title_english_share=0.1538; title_reads=english; abstract_words=205; abstract_english_function_words=51; abstract_english_share=0.2488; abstract_reads=english; language_check=metadata_listed