Evaluation of an in-use chest CT protocol in lung cancer screening - A single institutional study
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Background Lung cancer is the most common cause of cancer-related death worldwide and therefore there has been a growing demand for low-dose computed tomography (LDCT) protocols. Purpose To investigate and evaluate the dose and image quality of patients undergoing lung cancer screening (LCS) using LDCT in Norway. Materials and Methods Retrospective dosimetry data, volumetric CT dose index (CTDI vol ) and dose-length product (DLP), from 70 average-size and 70 large-size patients who underwent LDCT scan for LCS were included in the survey. Effective dose and size-specific dose were calculated for each examination and were compared with the American Association of Physicists in Medicine (AAPM) requirement. For a quantitative image quality analysis, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were determined for different regions in the chest with two iterative reconstruction techniques, iDose and Iterative Model Reconstruction. Differences in dose and image quality between average-size and large-size patients were evaluated by Independent sample t test, and Wilcoxon signed rank test within the same patient group. Results The independent sample t test revealed significant differences ( p < .05) in dose values between average-size and large-size patients. Mean CTDI vol and DLP for average-size patients were 2.8 mGy and 115 mGy.cm, respectively, with appropriate increment for the large-size patients. Image quality (image noise, SNR, and CNR) did not significantly differ between patient groups when images were reconstructed with a model based iterative reconstruction algorithm. Conclusion The screening protocol assessed in this study resulted in CTDI vol values that were compliant with AAPM recommendation. No significant differences in objective image quality were found between patient groups.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=16; title_english_function_words=5; title_english_share=0.3125; title_reads=english; abstract_words=273; abstract_english_function_words=85; abstract_english_share=0.3114; abstract_reads=english; language_check=metadata_listed