Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Lung cancer detection by low-dose computerized tomography (LDCT) and digital tomosynthesis (DT) for lung cancer screening in a high-risk population: A comparison of detection methods.
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref, OpenAlex
- Free full text
- Not looked for in this run
Abstract
1530 Background: Low-dose computerized tomography (LDCT) recommended as a screening tool for lung cancer in a high risk population has some limitations with respect to its high false positive rate, accumulated radiation exposure and relatively high costs. Digital tomosynthesis (DT) is a multi-section imaging technique which can improve detection ability of small lung nodules and renders much lower radiation dosage and operation costs. Methods: 624 Thai heavy smokers (>30 pack-years) were enrolled in a prospective study starting from July 2012 to October 2013. All participants underwent LDCT and DT on the same day while the results were independently viewed with 1-week interval apart. Abnormal findings were categorized into 3 groups: negative, indeterminate (maximum diameter of pulmonary nodule 5-9.9 mm or volume 50-500 mm3), and suspicious for primary lung cancer (maximum diameter of pulmonary nodule >10 mm or volume >500 mm3, consolidation, obstructive atelectasis, pleural effusion, or mediastinal lymphadenopathy). Results: Ten lung cancer cases were detected in this high-risk group (10/624, 1.6%). LDCT and DT classified 23 and 20 cases, respectively, as suspicious for primary lung cancer. DT detected 8 primary lung cancers as frequently as did LDCT. LDCT classified 68 cases as indeterminate while DT classified 21 as such cases. Two additional primary lung cancers were detected at a 3-month follow-up; all were identified as indeterminate by baseline LDCT and only one case was indeterminate by baseline DT. The positive predictive value (PPV) for all suspicious for primary lung cancer findings by LDCT and DT was 34.8% and 40%, respectively. The sensitivity and specificity of LDCT and DT was comparable at 80% and 98%, respectively. The PPV for pulmonary nodule >10 mm or volume >500 mm3 was 30% and 42% in LDCT and DT, respectively. The PPV for pulmonary nodule >5mm or volume 50-500 mm3 was 9% and 22.5% in LDCT and DT, respectively. Conclusions: DT is a lung cancer screening modality that is comparable to LDCT, particularly for pulmonary lesions of 10 mm. and larger.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=27; title_english_function_words=7; title_english_share=0.2593; title_reads=english; abstract_words=302; abstract_english_function_words=103; abstract_english_share=0.3411; abstract_reads=english; language_check=metadata_listed