Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Hounsfield Units measured in low dose CT reliably assess vertebral trabecular bone density changes over two years in axial spondyloarthritis

Mary Lucy Marques; Nuno Pereira da Silva; Désirée M F M van der Heijde; M. Reijnierse; Xenofon Baraliakos; Jürgen Braun; Floris A van Gaalen; Sofía Ramiro (2022). Seminars in Arthritis and Rheumatism

DOI 10.1016/j.semarthrit.2022.152144

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVES: To describe low dose Computed Tomography (ldCT) Hounsfield Units (HU) two-year change-from-baseline values (expressing trabecular bone density changes) and analyse their inter-reader reliability per vertebra in radiographic axial spondyloarthritis (r-axSpA). METHODS: We used 49 patients with r-axSpA from the multicentre two-year Sensitive Imaging in Ankylosing Spondylitis (SIAS) study. LdCT HU were independently measured by two trained readers at baseline and two years. Mean (standard deviation, SD) for the change-from-baseline HU values were provided per vertebra by reader. Intraclass correlation coefficients (ICC; absolute agreement, two-way random effect), Bland-Altman plots and smallest detectable change (SDC) were obtained. Percentages of vertebrae in which readers agreed on the direction of change and on change >|SDC| were computed. RESULTS: Overall, 1,053 (98% of all possible) vertebrae were assessed by each reader both at baseline and two years. Over two years, HU mean change values varied from -23 to 28 and 29 for reader 1 and 2, respectively. Inter-reader reliability of the two-year change-from-baseline values per vertebra was excellent: ICC:0.91-0.99; SDC:6-10; Bland-Altman plots were homoscedastic, with negligible systematic error between readers. Readers agreed on the direction of change in 88-96% and on change >|SDC| in 58-94% of vertebrae, per vertebral level, from C3 to L5. Overall, similar results were obtained across all vertebrae. CONCLUSION: LdCT measurement of HU is a reliable method to assess two-year changes in trabecular bone density at each vertebra from C3-L5. Being reliable across all vertebrae, this methodology can aid the study of trabecular bone density changes over time in r-axSpA, a disease affecting the whole spine.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=3; title_english_share=0.1500; title_reads=english; abstract_words=265; abstract_english_function_words=82; abstract_english_share=0.3094; abstract_reads=english; language_check=metadata_listed