Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Use of a single-scan Lung-RADS for pulmonary nodule assessment in resource-limited clinical settings
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: Lung carcinoma remains the leading cause of cancer-related mortality worldwide, with a similar high burden in Asia. While Lung-RADS v2022 was developed to standardize lung cancer screening using low-dose CT (LDCT), its reliance on follow-up imaging limits feasibility in low-resource settings. OBJECTIVE: To evaluate the diagnostic performance of Lung-RADS v2022 applied to a single baseline CT scan for pulmonary nodule characterization. METHODOLOGY: Baseline CT scans from 79 participants in the National Lung Screening Trial (NLST) were reviewed by two radiologists using Lung-RADS v2022. Nodules were classified as benign (categories 1-3) or malignant (categories 4A-4X). Histopathological diagnosis or ≥2 years of CT stability was taken as the reference standard. Diagnostic performance was assessed using cross-tabulation, logistic regression, and ROC analysis. RESULTS: The cohort comprised 45 men and 34 women (mean age: 62.9 years). Using single-scan Lung-RADS, sensitivity was 72% and specificity 90.7%, with overall accuracy of 84.8% and AUC of 0.79. Positive and negative predictive values were 78.3% and 87.5%, respectively. Chi-square analysis showed significant correlation between Lung-RADS categories and final diagnoses (p < 0.0001). The multivariate logistic regression model achieved sensitivity of 76.1%, specificity of 90.7%, and AUC of 0.92. CONCLUSION: Lung-RADS retains diagnostic value when applied to baseline scans alone, though with reduced sensitivity compared to longitudinal use. Spiculated margins and size >7 mm were the most robust predictors of malignancy. These findings support the applicability of single-scan Lung-RADS in resource-limited settings lacking follow-up CT access.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=16; title_english_function_words=4; title_english_share=0.2500; title_reads=english; abstract_words=238; abstract_english_function_words=65; abstract_english_share=0.2731; abstract_reads=english; language_check=metadata_listed