Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Axial Consistent Memory GAN With Interslice Consistency Loss for Low Dose Computed Tomography Image Denoising

Sutanu Bera; Prabir Kumar Biswas (2024). IEEE Transactions on Radiation and Plasma Medical Sciences

DOI 10.1109/trpms.2023.3260214

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Degradation of the diagnostic quality of Low Dose CT (LDCT) due to noise is a major bottleneck that hinders the widespread application of LDCT imaging as an alternative to standard-dose computed tomography (CT) imaging. Recent deep learning-based methods for denoising LDCT images utilizing interslice similarity of CT slices have shown promising results; however high computational cost of those methods is a significant bottleneck for practical deployment. This study introduces an alternative approach for utilizing the interslice similarity among the CT slices for LDCT denoising. First, we propose a novel memory network that remembers the aggregate information about the previous slices and uses it to denoise the contemporary slice. Next, we proposed a novel axial consistent discriminator network and a novel interslice consistency loss to assist the memory network in learning the interslice information flow. Our proposed discriminator network works both as a spatial discriminator and a volume discriminator. The proposed loss appeals to the network to generate an output consistent with the previous axial slice, consequently helping to suppress the artifacts present in the current slice. The extensive experiment on two publicly available datasets validates that our method performs favorably against the existing state-of-the-art methods.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=200; abstract_english_function_words=69; abstract_english_share=0.3450; abstract_reads=english; language_check=metadata_missing