Radiation Dose Reduction of Computed Tomography in Complex Distal Femur Fractures: A Cadaver Study to Develop a Low Dose Scanning Protocol

Nicholas O'Neill; Samuel J. Wisniewski; Michael Adams; James Peters; Michael Wagner (2019). Spartan Medical Research Journal

DOI 10.51894/001c.8105

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

CONTEXT Recent advances in diagnostic imaging have made computed tomography (CT) a widely used test in trauma patients. Consequently, the collective radiation burdened sustained by this patient population has increased substantially. The purpose of this cadaveric study was to determine if a significantly lowered CT radiation dose protocol would provide adequate imaging studies for the surgeon, using the distal femur as a model. METHODS Ten adult cadaveric knee specimens were used to create Orthopaedic Trauma Association (AO/OTA) 33-C3 distal femur fractures with associated coronal plane Hoffa fractures and varying intra-articular displacements. Using a single CT scanner, each cadaver was scanned at 5 separate protocols defined by sequentially lowered radiation doses, the highest of which was one-third the value of our institution’s current protocol. These images were then evaluated by fellowship-trained orthopedic surgeons, an orthopedic trauma fellow, and residents. Observer reliability and confidence levels were calculated for measuring fracture displacement, assessing the quality of 3D reconstructions, and developing treatment plans. RESULTS Across all reviewers and specimens, there was an average difference of 0.66 millimeters (mm) between the measured fracture gap and true fracture gap. The highest intraclass correlation coefficient (ICC) calculated for the inter-rater reliability of gap measurements was 0.983 at 75 mAs (95% CI: 0.955-0.996), followed by 0.973 (95% CI: 0.930-0.993) and 0.958 (95% CI: 0.896-0.988) at 15 mAs and 60 mAs, respectively. All 3D reconstructions obtained at 75 mAs and 45 mAs values (N = 8) were of acceptable imaging quality to all reviewers, while only 3 of 4 3D reconstructions obtained at 15 mAs were considered acceptable. There was no difference in treatment plans across all reviewers, regardless of radiation dose. CONCLUSIONS In summary, our results indicate that CT scans of complex distal femur fractures at one-third the amount of radiation exposure may provide adequate imaging necessary to develop an appropriate treatment plan. At significantly lowered doses, the reviewers were able to accurately measure the amount of fracture displacement and identify the presence of each Hoffa fracture. Future studies are necessary to compare this protocol’s diagnostic capacity and limitations in evaluating complex fractures with that of our institution’s standard protocol in a clinical setting.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=5; title_english_share=0.2381; title_reads=english; abstract_words=344; abstract_english_function_words=118; abstract_english_share=0.3430; abstract_reads=english; language_check=metadata_listed