Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-Activity 124I-PET/Low-Dose CT Versus 131I Probe Measurements in Pretherapy Assessment of Radioiodine Uptake in Benign Thyroid Diseases

Julian Georg Westphal; Thomas Winkens; Christian Kühnel; Martin G. Freesmeyer (2014). The Journal of Clinical Endocrinology & Metabolism

DOI 10.1210/jc.2013-4390

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

CONTEXT: Radioiodine therapy of benign thyroid diseases requires pretherapy assessment of radioactive iodine uptake (RAIU) for reliable therapy planning. OBJECTIVE: Our objective was to assess RAIU by low-activity (124)I-positron emission tomography/low-dose computed tomography ((124)I-PET/CT) in comparison with standard (131)I probe measurements. DESIGN/SETTING: This prospective comparative study was conducted at the Jena University Hospital, Jena, Germany, in a referral center setting. PATIENTS: A total of 79 patients with benign thyroid diseases were screened, 40 of whom met the inclusion criteria (stable TSH, free T3 and free T4 levels; no thyroid-specific medication, no iodine contamination) and 24 of whom agreed to participate by signing an informed consent. INTERVENTIONS: All patients received the standard (131)I scintillation probe uptake test 30 hours after administration of 3 MBq (131)I. Seven days later, all patients were subjected to (124)I-PET/CT uptake measurement 30 hours after administration of 1 MBq (124)I. MAIN OUTCOME MEASURES: The decay-corrected uptake values of both techniques were compared. Additionally, 3 different volume-of-interest-based evaluation methods in PET/CT (whole neck [WN], automatic isocontour [IC], and manually contoured [MC]) were evaluated. RESULTS: The (131)I probe measurement and (124)I-PET.WN method provided very similar mean RAIU (30.7% ± 10.3%; 31.7% ± 8.9%), resulting in a significant positive correlation (r = 0.93, P < .001). Compared with (124)I-PET.WN, the (124)I-PET.IC (29.8% ± 8.6%) and the (124)I-PET.MC (24.5% ± 7.1%) demonstrated lower uptake values. CONCLUSIONS: Using activities as low as 1 MBq, the (124)I-PET.WN method shows a good correlation with conventional (131)I probe measurement. Thus, (124)I-PET/CT is a suitable alternative for pretherapy RAIU evaluations. This may offer potential additional benefits such as PET/ultrasound fusion imaging and CT volumetry.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=3; title_english_share=0.1429; title_reads=english; abstract_words=271; abstract_english_function_words=69; abstract_english_share=0.2546; abstract_reads=english; language_check=metadata_listed