Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

The feasibility of low-dose CT protocols for coronary artery calcium scoring and PET attenuation correction in cardiac PET/CT

Tung-Hsin Wu; Kun-Mu Lu; Nien‐Yun Wu; Shyh‐Jen Wang; Greta S. P. Mok; Bang‐Hung Yang; Ching‐Ching Yang (2014). Nuclear Medicine Communications

DOI 10.1097/mnm.0000000000000251

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

INTRODUCTION: The purpose of this study was to investigate the feasibility of using low-dose computed tomography (CT) in coronary artery calcium scoring and PET attenuation correction for patients in different weight categories undergoing cardiac PET/CT examinations. MATERIALS AND METHODS: Calcium scoring computed tomography (CSCT) scans and PET scans of anthropomorphic cardiac phantoms simulating normal-weight, mildly obese, and severely obese patients were acquired with a hybrid PET/CT scanner. CSCT images were acquired at 120 kVp, with tube current ranging from 10 to 550 mA. PET scans were performed in three-dimensional mode, with acquisition time of 3 min/bed position. The image quality of cardiac PET/CT was evaluated by assessing the signal-to-noise ratio. CT-based coronary artery calcium quantification was performed using the Agatston scoring system. RESULTS: On the basis of our results, the CSCT protocols using tube currents of 50 and 150 mA should be able to achieve the lowest possible radiation dose while maintaining the desired image quality for normal-weight and mildly obese patients undergoing cardiac PET/CT examinations, respectively. When the proposed low-dose CSCT protocols were performed, radiation dose could be reduced by 83.34 and 50% compared with those from CSCT scans acquired with standard tube current settings for normal-weight and mildly obese patients, respectively. In the scanning of severely obese patients, an increase in tube voltage or current would help improve the reliability of image information provided by cardiac PET/CT. CONCLUSION: Our study demonstrated the feasibility of low-dose CT protocols for coronary artery calcium scoring and PET attenuation correction in cardiac PET/CT to examine patients in different weight categories. The calculations performed in this work should be able to provide practical information to achieve necessary diagnostic information while keeping radiation dose as low as reasonably achievable.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=5; title_english_share=0.2500; title_reads=english; abstract_words=294; abstract_english_function_words=91; abstract_english_share=0.3095; abstract_reads=english; language_check=metadata_listed