Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Abstract 175: Dual source 128-slice computed tomography coronary angiography: A low radiation paradigm in evaluation of Kawasaki disease at Chandigarh, North India
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Objective: To evaluate the feasibility of low dose computed tomography coronary angiography (CTCA) on a dual source scanner in children on follow up for Kawasaki disease (KD). Methods: A prospective study comprising 20 consecutive children with KD was conducted from November 2013 to August 2014 on 128-dual source second generation Siemens Definition Flash with either prospective or retrospective electrocardiographic (ECG) gating. A radiologist blinded to the clinical profile and echocardiography (ECHO)/ stress thallium data evaluated each scan. Peak Kilovolts (KVp), milliampere (mA) and radiation dose (dose length product-mGycm and effective dose milliSieverts-mSv) were recorded. Another radiologist correlated CTCA data with clinical/ other imaging data. Results: Demographic/ clinical data and scan parameters are given in Table. Mean effective dose was 1.25 mSv (range 0.22 to 2.74), with prospective ECG gating in 8 patients, it was even lower (0.22 to 0.91 mSv). Six of the 20 patients showed abnormalities including ectasia (n=3), aneurysm (n=2) and stenosis (n=3). More than one abnormality was seen in 2 patients. Four children with normal ECHO had abnormalities detected on CTCA. Stress thallium scintiscan had been performed in 16 patients with mild/ moderate reversible perfusion defects detected in 14. Six of 14 patients with moderate perfusion abnormalities had an abnormal CTCA. Conclusion: In our experience, dual source CTCA is a feasible low radiation dose modality in evaluation in patients with KD. Future impact: Dual source CTCA has potential to be standard of care for evaluation of coronary artery abnormalities in KD.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=21; title_english_function_words=4; title_english_share=0.1905; title_reads=english; abstract_words=232; abstract_english_function_words=71; abstract_english_share=0.3060; abstract_reads=english; language_check=metadata_listed