Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low contrast and radiation dose coronary CT angiography using a 320-row system and a refined contrast injection and timing method

Seitaro Oda; Daisuke Utsunomiya; Hideaki Yuki; Noriyuki Kai; Masahiro Hatemura; Yoshinori Funama; Masafumi Kidoh; Morikatsu Yoshida; Tomohiro Namimoto; Yasuyuki Yamashita (2015). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2014.12.002

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: Among CT scanners, 320-row instruments feature decreased photon energy and yield strong contrast enhancement. Consequently, the contrast medium (CM) dose can be reduced. The results of low-tube-voltage coronary CT angiography (CCTA) performed on 320-row scanners have not been adequately assessed. OBJECTIVE: We evaluated the effects of a low-contrast-dose protocol on the image quality of CCTA using 80 kVp tube voltage, iterative reconstruction (IR), and a 320-row scanner. METHODS: We randomly assigned 90 patients (mean body weight, 56.5 ± 11.0 kg) to 1 of 3 CCTA protocols. Under protocol A, 30 were scanned using a conventional 120-kVp protocol and a standard CM dose (280 mg iodine/kg body weight [mgI/kg]). Another 30 underwent scanning at 80 kVp with a 25% CM dose reduction (210 mgI/kg; protocol B). Under protocol C, the remaining 30 patients were scanned at 80 kVp with a 50% CM dose reduction (140 mgI/kg). The 120 and 80 kVp images were processed with IR. Images obtained under the 3 protocols were subjected to quantitative and qualitative analysis. RESULTS: The amount of CM used in protocol A, B, and C was 43.6 ± 10.1, 30.3 ± 4.4, and 21.0 ± 4.0 mL, respectively. Mean CT attenuation of the coronary arteries tended to be higher under protocol B than the other 2 protocols. The contrast-to-noise ratio was significantly higher under protocol B. The mean visual scores were significantly higher for protocols A and B than protocol C. The mean effective radiation dose was significantly lower under the 80-kVp protocol. CONCLUSION: With a 320-row scanner and our refined CM injection and timing protocol, it is technically feasible to obtain sufficient vascular enhancement with a reduction in the CM and/or radiation dose at 80-kVp CCTA with IR.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=5; title_english_share=0.2500; title_reads=english; abstract_words=266; abstract_english_function_words=91; abstract_english_share=0.3421; abstract_reads=english; language_check=metadata_listed