Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A31-18 Evaluation of the Sybil Artificial Intelligence Model for Lung Cancer Prediction for Use in Lung Cancer Screening at the Department of Veterans Affairs

Alexey Kotlik; R B Fricks; Michael Gilkey; H Al-Shakhshir; A Madabhushi; Nhan Do; Scott L. Shofer (2026). American Journal of Respiratory and Critical Care Medicine

DOI 10.1093/ajrccm/aamag162.3634

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Rationale Sybil is a deep learning model developed for early lung cancer prediction using low dose Computed tomography (LDCT), trained on the National Lung Screening Trial (NLST), and validated multi-institutionally. While the model demonstrated high predictive performance for risk prediction of onset of new lung cancers, its generalizability to the unique population and clinical environment at the Department of Veterans Affairs (VA) remains uncertain. We evaluated Sybil on an independent cohort from the VA Lung Cancer Screening (LCS) study to assess its robustness and clinical applicability in a regional veteran cohort. Methods We retrospectively analyzed LDCT imaging data from 1,903 veterans enrolled in LCS in regions served by Durham VA Medical Center. Among these patients, 46 were diagnosed with lung cancer within one year from the initial imaging study. Unlike the original Sybil study, which evaluated the model’s ability to predict cancer risk up to six years into the future, our evaluation focused on the model’s performance in identifying patients at risk of developing lung cancer within one year of their initial screening visit. The pretrained Sybil ensemble was applied without retraining or fine-tuning. We evaluated model performance using area under the receiver operating characteristic curve (ROC AUC) and average precision (AP), with 95% confidence intervals (CI) estimated via bootstrapping. For comparison we calculated the same metrics on the test subset of NLST used in the original study, with 2,328 patients of whom 38 developed cancer within a year of enrollment in NLST. Results On the NLST test set, Sybil achieved a ROC AUC of 0.93 (95% CI: 0.88-0.97) and an AP of 0.44 (95% CI: 0.26-0.60), consistent with previously published results. However, when applied to the VA LCS cohort, performance declined significantly, with a ROC AUC of 0.81 (95% CI: 0.74-0.87) and an AP of 0.17 (95% CI: 0.09-0.28). These findings indicate a substantial drop in predictive accuracy and precision, suggesting limited generalizability of Sybil to a representative sample of the veteran population and our clinical environment. Conclusions Applying Sybil to the Durham VA LCS cohort resulted in reduced performance compared to original metrics on the NLST dataset. This highlights the challenges of deploying AI models across heterogenous populations and clinical settings. Differences in demographics, comorbidities, imaging protocols, and evaluation timeframes may contribute to this performance gap. These results emphasize the need for external validation and potential model adaptation before deployment in new clinical settings. This abstract is funded by: This research was supported in part by the Department of Veterans Affairs Cooperative Studies Program

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=24; title_english_function_words=9; title_english_share=0.3750; title_reads=english; abstract_words=404; abstract_english_function_words=136; abstract_english_share=0.3366; abstract_reads=english; language_check=metadata_listed