Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Diagnostic accuracy of low-dose dual-source cardiac computed tomography as compared to surgery in univentricular heart patients

Narumol Chaosuwannakit; Pattarapong Makarawate (2018). Journal of Cardiothoracic Surgery

DOI 10.1186/s13019-018-0729-2

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: To evaluate the ability of low radiation dose dual-source computed tomography (DSCT) to depict the features of morphological univentricular heart and to define accuracy by comparing findings with surgery. METHODS: Low radiation dose dual-source cardiac computed tomography (CCT) of 33 cases of functional univentricular heart preliminary diagnosis by echocardiography compared with the results of surgery were retrospectively analyzed (aged 1 day to 4 years, median 5 months). The appropriate dose reduction strategies and iterative reconstruction were applied. RESULTS: Thirty three univentricular heart patients were classified into three types according to Anderson's classification method, including 16 cases (48.5%) univentricular of right ventricular type with rudimentary chamber of left ventricle, 11 cases (33.3%) univentricular of left ventricular type with rudimentary chamber of right ventricle and 6 cases (18.2%) univentricular heart of indeterminate type without rudimentary chamber. The extracardiac malformation such as hypoplastic aortic arch, coronary artery fistula, total anomalous pulmonary venous returns or hypoplastic lung were presented frequently. The overall sensitivity and specification of cardiac CT was 100% compared to the results of surgery. The procedural dose-length product was 18 ± 5 mGy-cm, and unadjusted and adjusted radiation doses were 0.25 and 0.64 mSv, respectively. CONCLUSION: Cardiac CT can diagnose accurately and be performed with a low radiation exposure in patients with the functional univentricular heart disease. The aorta, pulmonary artery and lung can be evaluated completely and simultaneously as well. Cardiac CT is an effective advanced non-invasive imaging modality to comprehensive evaluation the functional univentricular heart patients, particularly if cardiac MRI poses a high risk or is contraindicated.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=248; abstract_english_function_words=73; abstract_english_share=0.2944; abstract_reads=english; language_check=metadata_listed