Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Advanced MRI Sequences for Structural Lesion Assessment in Sacroiliitis

Törehan Özer; Hafize Emine Sonmez; Yonca Akgoz ANIK (2026). Diagnostics

DOI 10.3390/diagnostics16060887

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background/Objectives: Assessing structural damage in pediatric sacroiliitis is challenging, necessitating radiation-free alternatives to computed tomography (CT). This study evaluated the diagnostic performance of advanced MRI sequences—3D-MENSA (Multi-Echo in Steady-State Acquisition), 3D-MERGE (Multiple-Echo Recombined Gradient Echo), and Zero Echo Time (ZTE)—against conventional T1-weighted sequences for detecting structural lesions. Low-dose computed tomography (LDCT) served as the reference standard. A secondary objective was to qualitatively assess the visibility of active inflammatory lesions and fat metaplasia. Methods: In this cross-sectional study, 23 pediatric patients with enthesitis-related arthritis (ERA) were included. To adhere strictly to radiation safety principles, the study used pre-existing ldCT datasets from a clinical cohort as the reference standard. No new CT scans were performed for this study. Structural lesions (erosions, sclerosis, and joint-space changes) were independently scored by two blinded radiologists. Interobserver agreement was assessed using intraclass correlation coefficients (ICC). Results: Advanced sequences (ZTE, 3D-MENSA, 3D-MERGE) demonstrated high agreement with ldCT for erosion detection (ICC range: 0.924–0.998) and significantly outperformed conventional T1-weighted MRI (ICC: 0.707). 3D-MENSA provided distinct contrast, effectively differentiating the ligamentous component of the sacroiliac joint from both the synovial component and the adjacent bone cortex. Qualitatively, 3D-MENSA also identified bone marrow edema and fat metaplasia, which cannot be visualized by ZTE or ldCT. Conclusions: 3D-MENSA and 3D-MERGE enable comprehensive evaluation of structural sacroiliitis lesions in pediatric patients with diagnostic accuracy comparable to ldCT. Specifically, 3D-MENSA demonstrates the potential to detect both active and chronic lesions in a single, rapid, radiation-free acquisition. These findings suggest that it should be considered for routine pediatric imaging protocols.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=2; title_english_share=0.2222; title_reads=english; abstract_words=277; abstract_english_function_words=70; abstract_english_share=0.2527; abstract_reads=english; language_check=metadata_listed