Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Anisotropic Total Variation Denoising Technique for Low-Dose Cone-Beam Computed Tomography Imaging

Ho Lee; Jeongmin Yoon; Eungman Lee (2018). Progress in Medical Physics

DOI 10.14316/pmp.2018.29.4.150

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

This study aims to develop an improved Feldkamp-Davis-Kress (FDK) reconstruction algorithm\nusing anisotropic total variation (ATV) minimization to enhance the image quality of low-dose conebeam\ncomputed tomography (CBCT). The algorithm first applies a filter that integrates the Shepp-\nLogan filter into a cosine window function on all projections for impulse noise removal. A total\nvariation objective function with anisotropic penalty is then minimized to enhance the difference\nbetween the real structure and noise using the steepest gradient descent optimization with\nadaptive step sizes. The preserving parameter to adjust the separation between the noise-free and\nnoisy areas is determined by calculating the cumulative distribution function of the gradient\nmagnitude of the filtered image obtained by the application of the filtering operation on each\nprojection. With these minimized ATV projections, voxel-driven backprojection is finally performed\nto generate the reconstructed images. The performance of the proposed algorithm was evaluated\nwith the catphan503 phantom dataset acquired with the use of a low-dose protocol. Qualitative\nand quantitative analyses showed that the proposed ATV minimization provides enhanced CBCT\nreconstruction images compared with those generated by the conventional FDK algorithm, with a\nhigher contrast-to-noise ratio (CNR), lower root-mean-square-error, and higher correlation. The\nproposed algorithm not only leads to a potential imaging dose reduction in repeated CBCT scans\nvia lower mA levels, but also elicits high CNR values by removing noisy corrupted areas and by\navoiding the heavy penalization of striking features.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=1; title_english_share=0.0769; title_reads=not_english; abstract_words=245; abstract_english_function_words=80; abstract_english_share=0.3265; abstract_reads=english; language_check=metadata_listed