Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Generalized iterative sparse-view CT reconstruction with deep neural network

Ting Su; Xindong Sun; Xiaolei Deng; Hairong Zheng; Dong Liang; Yongshuai Ge (2020). SPIE Medical Imaging: Physics of Medical Imaging

DOI 10.1117/12.2547739

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (CT) has attracted much attention in clinical applications since X-ray radiations can cause serious health risks to patients. Sparse-view CT imaging is one of the major ways to reduce radiation dose. However, if reconstructing the sparse-view CT images with conventional filtered backprojection (FBP) algorithm, image quality may be significantly degraded due to the severe streaking artifacts. Therefore, iterative sparse-view CT image reconstruction (IR) algorithms have been developed and utilized to improve image quality. One drawback of using the IR algorithms is they usually spend long computation time. Additionally, adjusting and optimizing the hyper-parameters that are needed during iteration procedures is also time-consuming, some- times may even depend on individual experience. These potential drawbacks strongly limit the wide applications of IR algorithms. Aiming at partially overcome such difficulties, in the present work, we propose a deep iterative reconstruction (DIR) framework to generalize the conventional IR algorithms by mapping them into the deep neural network (DNN) technique. With this proposed DIR algorithms, the prior term, the data fidelity term, and the hyper-parameters can all be represented and learned by network. By doing so, some generalized iterative models can be used to perform high quality sparse-view CT image reconstructions. Numerical experiments based on clinical patient data demonstrated that the proposed DIR algorithms can mitigate the streaking artifacts more effectively while well preserving the subtle structures.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=10; title_english_function_words=1; title_english_share=0.1000; title_reads=english; abstract_words=234; abstract_english_function_words=76; abstract_english_share=0.3248; abstract_reads=english; language_check=metadata_listed