Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Stone-Free Rate after Treating Kidney Stones Exceeding 10 mm via Flexible Ureteroscopy: Can Endoscopic Assessment Replace Low-Dose Computed Tomography Control?

Konrad Wilhelm; Oliver Hahn; Martin Schoenthaler; Simon Hein; Jakob Neubauer; Marco Julius Schnabel; Andreas Neisius (2019). Urologia Internationalis

DOI 10.1159/000502264

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

INTRODUCTION: It is unclear whether endoscopic assessment of the stone-free rate after flexible ureteroscopy (fURS) is as effective as assessment with low-dose computed tomography (CT) scan. METHODS: Prospective documentation of patients with kidney stones > 10 mm diameter from 2 different centers (Freiburg, Regensburg), who underwent fURS and were declared to be endoscopically completely stone-free. Low-dose CT control performed 4-8 weeks postoperatively. RESULTS/CONCLUSION: Thirty-eight patients were treated between October 2015 and August 2016 (12 F, 26 M). Average age was 55.9 years (range 19-82, SD 17.24), and body mass index was 29.7 kg/m2 (range 23.5-42.5, SD 4.37). There were 2.0 (range 1-7, SD 1.55) stones with a mean diameter of 15 mm (range 10-40, SD 6.78) per kidney. Mean surgery time was 74 min (range 38-124, SD 24.28), and lithotripsy was necessary in 33 cases. CT was performed 5.4 weeks afterwards (range 4-8, SD 1.43). One patient had a 2 mm residual which was extracted by URS. Strictly speaking, endoluminal stone removal control failed in only that patient, yielding a negative predictive value of 97%. A routine postoperative CT scan would thus appear unnecessary in the case of negative endoscopic control for residual fragments and should be avoided to reduce radiation exposure. Further investigations with larger patient populations are necessary.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=2; title_english_share=0.0952; title_reads=not_english; abstract_words=188; abstract_english_function_words=57; abstract_english_share=0.3032; abstract_reads=english; language_check=metadata_listed