Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Radiation dose-aware sinogram knowledge library transformer with feature modulation for low-dose medical image segmentation

Yeong Jong Lee; Do Hyun Ki; Seung-hyeok Back; Seok Bong Yoo (2026). Computers in Biology and Medicine

DOI 10.1016/j.compbiomed.2026.111787

Exclude AI

Does not meet: The study presents original human clinical data on low-dose computed tomography screening for lung cancer.

Decided by
The AI (Claude Haiku 4.5)
Basis
Abstract
Found in
OpenAlex
Free full text
Not looked for: free full text is sought only for some studies
Flagged
The AI's reasoning contradicts its call. Check it on the Flagged tab

Abstract

Low-dose computed tomography (LDCT) and low-dose positron emission tomography (LDPET) enable shorter acquisition times and lower radiation exposure. However, dose reduction leads to low-count data, which increases noise and variance and can introduce structured artifacts. These degradations hinder reliable clinical interpretation by reducing lesion contrast and obscuring lesion boundaries, thereby compromising segmentation accuracy. Although deep learning approaches have been proposed to reconstruct and segment low-dose images to full-dose quality, many existing methods address dose variation without explicitly modeling the relationship between dose reduction and image degradation. Moreover, some methods assume externally provided dose metadata as a conditioning input, which can limit applicability and generalization when such metadata are missing, non-standardized, or defined inconsistently across datasets and protocols. Therefore, this work proposes the radiation dose-aware sinogram knowledge library transformer with feature modulation for low-dose medical image segmentation (SinoDose). The main novelty of SinoDose is that it estimates an observation-driven visual relative dose (VR-dose) directly from sinogram-domain internal cues, rather than relying on external dose metadata. In addition, a learnable sinogram knowledge library (SKL) injects acquisition-domain periodic priors to compensate for structures that collapse or become distorted under extremely low-dose conditions. The estimated VR-dose and its context vector are then used in dose-guided calibrated FiLM to enable dose-adaptive joint reconstruction and lesion segmentation in a unified framework. Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines. Additional evaluation on the real low-dose UDPET and the real-world LDCT datasets further supports reconstruction robustness under practical acquisition conditions. The code is available at https://github.com/yeongjong0220/DoseSino.

From PubMed.

The criteria

  • Include if: The study presents original human clinical data on low-dose computed tomography screening for lung cancer.
    Does not meet AI
    From the abstract: Low-dose computed tomography (LDCT) and low-dose positron emission tomography (LDPET) enable shorter acquisition times and lower radiation exposure.
    From the abstract: Therefore, this work proposes the radiation dose-aware sinogram knowledge library transformer with feature modulation for low-dose medical image segmentation (SinoDose).
    From the abstract: The estimated VR-dose and its context vector are then used in dose-guided calibrated FiLM to enable dose-adaptive joint reconstruction and lesion segmentation in a unified framework.
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
  • Include if: The study reports outcomes related to mortality, survival, early detection, illness, or disability in screened populations.
    Does not meet AI
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
    From the abstract: Additional evaluation on the real low-dose UDPET and the real-world LDCT datasets further supports reconstruction robustness under practical acquisition conditions.
  • Exclude if: Abstracts or meeting presentations.
    Does not apply AI
    From the record details: Source: OpenAlex; Type: article; Venue: Computers in Biology and Medicine; Date: 2026-06-04; Language: en; Host: doi.org; Abstract source: PubMed
  • Exclude if: Review articles or opinion pieces.
    Does not apply AI
    From the abstract: Therefore, this work proposes the radiation dose-aware sinogram knowledge library transformer with feature modulation for low-dose medical image segmentation (SinoDose).
    From the abstract: The main novelty of SinoDose is that it estimates an observation-driven visual relative dose (VR-dose) directly from sinogram-domain internal cues, rather than relying on external dose metadata.
    From the abstract: In addition, a learnable sinogram knowledge library (SKL) injects acquisition-domain periodic priors to compensate for structures that collapse or become distorted under extremely low-dose conditions.
    From the abstract: The estimated VR-dose and its context vector are then used in dose-guided calibrated FiLM to enable dose-adaptive joint reconstruction and lesion segmentation in a unified framework.
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
  • Exclude if: Animal studies or laboratory experiments.
    Does not apply AI
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
    From the abstract: Additional evaluation on the real low-dose UDPET and the real-world LDCT datasets further supports reconstruction robustness under practical acquisition conditions.
  • Exclude if: Studies on emphysema or asbestos exposure.
    Does not apply AI
    From the abstract: Low-dose computed tomography (LDCT) and low-dose positron emission tomography (LDPET) enable shorter acquisition times and lower radiation exposure.
    From the abstract: Therefore, this work proposes the radiation dose-aware sinogram knowledge library transformer with feature modulation for low-dose medical image segmentation (SinoDose).
  • Exclude if: Cost-effectiveness analyses or economic evaluations.
    Does not apply AI
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
  • Exclude if: Microsimulation or mechanistic modeling studies.
    Does not apply AI
    From the abstract: Therefore, this work proposes the radiation dose-aware sinogram knowledge library transformer with feature modulation for low-dose medical image segmentation (SinoDose).
    From the abstract: The estimated VR-dose and its context vector are then used in dose-guided calibrated FiLM to enable dose-adaptive joint reconstruction and lesion segmentation in a unified framework.
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
  • Exclude if: Studies with fewer than 10 cases.
    Unclear AI
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
    From the abstract: Additional evaluation on the real low-dose UDPET and the real-world LDCT datasets further supports reconstruction robustness under practical acquisition conditions.
  • Exclude if: Studies not involving human subjects.
    Applies AI
    From the abstract: Therefore, this work proposes the radiation dose-aware sinogram knowledge library transformer with feature modulation for low-dose medical image segmentation (SinoDose).
    From the abstract: The estimated VR-dose and its context vector are then used in dose-guided calibrated FiLM to enable dose-adaptive joint reconstruction and lesion segmentation in a unified framework.
    From the abstract: Experiments on the annotated AutoPET and KiTS datasets show that SinoDose consistently improves DSC, HD95, PSNR, and rPSNR over competing baselines.
    From the abstract: Additional evaluation on the real low-dose UDPET and the real-world LDCT datasets further supports reconstruction robustness under practical acquisition conditions.
  • Exclude if: Non-English language publications.
    Does not apply AI
    From the record details: Source: OpenAlex; Type: article; Venue: Computers in Biology and Medicine; Date: 2026-06-04; Language: en; Host: doi.org; Abstract source: PubMed
  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=2; title_english_share=0.1250; title_reads=english; abstract_words=284; abstract_english_function_words=79; abstract_english_share=0.2782; abstract_reads=english; language_check=metadata_listed

Each quote is copied word for word from the text the AI read, and checked against it by code.