Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Dose optimization in computed tomography of brain using CARE kV and CARE Dose 4D

Pooja Shah; Amish Sharma; Jayanti Gyawali; Sharma Paudel; Shanta Lall Shrestha; Surendra Maharjan (2018). Radiography Open

DOI 10.7577/radopen.3110

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Background: Computed Tomography (CT) scan of brain is the most widely used CT examination. Latest CT scanners have the potential to deliver very low radiation dose by utilizing tube potential and tube current modulation techniques. We aim to determine the application of CARE kV (tube potential modulation) and CARE Dose4D (tube current modulation) in CT scan of brain. Both CARE kV and CARE Dose4D are well-established innovative technology of Siemens Medical Solutions. Methodology: A prospective hospital-based study was conducted during four months at Tribhuvan University Teaching Hospital (TUTH). The data were collected on a Siemens Somatom Definition Edge 128 slices CT scanner. Non-random purposive sampling technique was employed. Ethical approval and consent to participate were taken for every participant. Non-contrast (NC) CT images were acquired without using CARE kV and CARE Dose4D, whereas during contrast-enhanced (CE) investigation, both were turned on keeping other scanning parameters constant for each individual. Results: A total of 72 patients, 42 males and 28 females - mean age 41y (range 16-87y) participated in this study. The Body Mass Index (BMI) was 22.0, range 20.1-25.0. The mean value of Computed Tomography Dose Index (CTDI), Dose Length Product (DLP) and Effective Dose (ED) before and after switching on both CARE kV and CARE Dose4D were 58.19±0.35 and 39.67±3.59 milli-Gray (mGy), 946.67 and 652.58 mGy-cm, and 1.98 and 1.36 milli-Sievert (mSv) respectively. Conclusion: CARE kV and CARE Dose4D can reduce radiation dose in CT scan of brain without loss of image quality.

From Crossref.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=244; abstract_english_function_words=72; abstract_english_share=0.2951; abstract_reads=english; language_check=metadata_missing