Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Coronary artery calcium scoring assessment in ultra-low-dose chest computed tomography

Huawei Xiao; Xiangquan Wang; Panfeng Yang; Ling Wang; Jian Xu (2024). Clinical Imaging

DOI 10.1016/j.clinimag.2023.110045

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

OBJECTIVES: To investigate the effect of non-electrocardiogram (ECG) -triggered ultra-low-dose CT (ULD-CT) with different reconstruction protocols on coronary artery calcium (CAC) scoring assessment, compared with ECG-triggered CAC CT (CAC-CT). METHODS: This prospective study included 115 patients who underwent CAC-CT and ULD-CT scans under the same topogram images. CAC-CT adopted a prospective ECG-triggered sequential acquisition with a tube potential of 120 kV, and the reconstruction protocol was standard Qr36 + slice 3 mm (CACQr-3mm group). ULD-CT adopted a non-ECG-triggered high-pitch acquisition with a tube potential of Sn100 kV, and four groups of images (named ULDQr-3mm, ULDSa-3mm, ULDQr-1.5mm, and ULDSa-1.5mm) were reconstructed using different reconstruction algorithms (standard Qr36, kV-independent Sa36) and slice thicknesses (3 mm, 1.5 mm). The accuracy of CAC detection by ULD-CT was calculated. The agreement of the CAC score between ULD-CT and CAC-CT scans was assessed using intraclass correlation coefficients (ICC) and Bland-Altman plot, and the agreement of risk categorization was assessed using weighted kappa. RESULTS: The sensitivity and specificity of the ULDSa-1.5mm group for detecting positive CAC were 100% and 97.4%, respectively (k = 0.980). The CAC score for the ULDSa-3mm and ULDSa-1.5mm groups demonstrated excellent agreement with the CACQr-3mm group (ICC = 0.992, 0.990, respectively), with a mean difference of -12.3 and - 12.4. The agreement of risk categorization based on absolute and percentile CAC score between the ULDSa-1.5mm and CACQr-3mm groups was excellent (weighted k = 0.954, 0.983, respectively), and risk reclassification rates were low (3.5%, 2.8%, respectively). The effective dose was reduced by approximately 77.2% for the ULD-CT compared to the CAC-CT (0.18 mSv vs. 0.79 mSv, p < 0.001). CONCLUSION: Reconstruction with a 1.5-mm slice thickness and kV-independent iterative algorithmic protocol in ULD-CT yielded excellent agreement in CAC score quantification and risk categorization compared with ECG-triggered CAC-CT.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=1; title_english_share=0.0833; title_reads=not_english; abstract_words=303; abstract_english_function_words=83; abstract_english_share=0.2739; abstract_reads=english; language_check=metadata_listed