Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Revisit FBP: analyze the tensor data after view-by-view backprojection

Jianhua Ma; Xi Tao; Yongbo Wang; Gang Yan; Hua Zhang; Wufan Chen (2019). SPIE Medical Imaging: Physics of Medical Imaging

DOI 10.1117/12.2512833

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

For a very long time, low-dose computed tomography (CT) imaging techniques have been performed by either preprocessing the projection data or regularizing the iterative reconstruction. The conventional filtered backprojection (FBP) algorithm is rarely studied. In this work, we show that the intermediate data during FBP possess some fascinating properties and can be readily processed to reduce the noise and artifacts. The FBP algorithm can be technically decomposed into three steps: filtering, view-by-view backprojection and summing. The data after view-by-view backprojection is naturally a tensor, which is supposed to contain useful information for processing in higher dimensionality. We here introduce a sorting operation to the tensor along the angular direction based on the pixel intensity. The sorting for each point in the image plane is independent. Through the sorting operation, the structures of the object can be explicitly encoded into the tensor data and the artifacts can be automatically driven into the top and bottom slices of the tensor. The sorted tensor also provides high dimensional information and good low-rank properties. Therefore, any advanced processing methods can be applied. In the experiments, we demonstrate that under the proposed scheme, even the Gaussian smoothing can be used to remove the streaking artifacts in the ultra-low dose case, with nearly no compromising of the image resolution. It is noted that the scheme presented in this paper is a heuristic idea for developing new algorithms of low-dose CT imaging.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=11; title_english_function_words=3; title_english_share=0.2727; title_reads=english; abstract_words=243; abstract_english_function_words=103; abstract_english_share=0.4239; abstract_reads=english; language_check=metadata_listed