Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Lung Nodule Segmentation Accuracy in CT Images Using YOLO, 3D-CNN, and Ensemble ViT-UNETR U-Net

Reyga Ferdiansyah Putra; Antoni Wibowo; Dewi Retno Sari Saputro (2026). Equivalent Jurnal Ilmiah Sosial Teknik

DOI 10.59261/jequi.v8i2.308

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background: Lung cancer is the leading cause of cancer-related mortality globally, with over 2.2 million new cases and 1.8 million deaths reported annually (WHO, 2022). Pulmonary nodule detection through low-dose computed tomography (LDCT) screening is the most effective method for early lung cancer identification. However, automated systems still face significant challenges: high false positive rates, limited sensitivity for micronodules (<5 mm), and poor segmentation accuracy for nodules with irregular morphology or juxtapleural attachment. Objective: Lung nodules early discovery is key to treating lung carcinoma, but even conventional systems' micronodules still have high false positives and low accuracy. Method: This study presents an end-to-end hybrid pipeline that uses the LUNA16 database to tackle this issue. The initial stage is to make use of YOLOv12 for Region of Interest (ROI) extraction, with 3D-CNN carrying out false positive filtering through volumetric verification as a gate. The final phase conducts pixel-level precision segmentation using Adaptive Bayesian Fusion on U-Net Residual 3D ensemble (local texture features) and ViT-UNETR (global anatomical context). Results: Experiments showed superior performance level 99.99% Accuracy, Mean Dice Similarity Coefficient (DSC) at 93.88% and IoU is 90.45%. The system was very robust, reaching 97.33% DSC in the micro nodule category (<5 mm). Conclusion: In summary, this integrated architecture delivers an objective, efficient and high-quality solution for automated Diagnosis.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=2; title_english_share=0.1176; title_reads=english; abstract_words=216; abstract_english_function_words=56; abstract_english_share=0.2593; abstract_reads=english; language_check=metadata_listed