Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Quadratic diffusion model with improved Mamba for low-dose CT blind super resolution

Xiebo Qiu; Xiaoqiang Zhao; Zhenrui Peng; Zhaoyang Song (2026). Measurement Science and Technology

DOI 10.1088/1361-6501/ae8d4c

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Low-dose computed tomography (LDCT) images are obtained by reducing the x-ray radiation dose, which can reduce the risk of radiation exposure to patients. However, LDCT images are usually blurry due to the decreased number of photons reaching the detectors, which makes it difficult to discern meaningful anatomies for clinical diagnosis. Super-resolution (SR) methods have been proposed to improve the quality of LDCT images without increasing the radiation dose. In this paper, we propose a novel LDCT blind SR method, named the quadratic diffusion model with improved Mamba (DMIM). Specifically, we design a kernel-guided degradation predictor, which takes advantage of a generative diffusion-based framework to predict the blur kernel in a low-resolution (LR) LDCT image. Meanwhile, to reconstruct more accurate LDCT images with detailed information, both the predicted blur kernel and the LR LDCT images as prior knowledge are input into our designed multi-perception feature reconstructor (MPF reconstructor). Moreover, we design an improved vision state space denoising module (IV-Mamba) to help the MPF reconstructor to better remove the noise in valuable diagnostic information. Extensive experiments on three public CT datasets with two scale factors demonstrate that the proposed DMIM achieves superior quantitative and qualitative performance. Compared with the best-performing competing result under each setting, DMIM yields average improvements of 0.43 dB in peak signal-to-noise ratio, 0.025 in SSIM, and 0.029 in modulation transfer function.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=2; title_english_share=0.1538; title_reads=english; abstract_words=232; abstract_english_function_words=70; abstract_english_share=0.3017; abstract_reads=english; language_check=metadata_listed