Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Computer-Aided Pulmonary Nodule Detection – Performance of Two CAD Systems at Different CT Dose Levels

Patrick A. Hein; Patrik Rogalla; C. Klessen; Alexander E. Lembcke; Valentina C. Romano (2009). RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren

DOI 10.1055/s-0028-1109394

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). MATERIALS AND METHODS: Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120 kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. RESULTS: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72 % and 62 % (CAD-1 vs. CAD-2) for SD-CT and with 73 % and 56 % for ULD-CT. Median false positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83 % and 61 % for SD-CT and to 89 % and 67 % for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p > 0.05). CONCLUSION: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=de; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=266; abstract_english_function_words=80; abstract_english_share=0.3008; abstract_reads=english; language_check=both_english