Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Diffusion-Augmented 3D Transformer for Robust Lung Cancer disease Screening on Low-Dose CT

A. Nivashini; Mehulkumar Kantaria; M. E. Paramasivam; S. Manochitra; G. Nirmalapriya; R Saravanakumar (2026). IEEE International Conference on Advances in Computing Research on Science Engineering and Technology (ACROSET)

DOI 10.1109/acroset70960.2026.11742502

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Lung disease screening using low-dose computed tomography has become important in identifying malignant nodules at an earlier and more treatable stage. Reliable automated analysis is therefore valuable for supporting radiologists in high-volume screening environments. However, low-dose computed tomography often contains noise, weak contrast, and large appearance variation, which makes small pulmonary nodules difficult to detect consistently. This challenge becomes more serious when benign structures and subtle lesions share similar visual patterns. Conventional computer-aided detection methods based on three-dimensional convolutional neural networks enhance the feature extraction process but lose the long-range context relationship. Transformer-based models enhance global representation, but their performance can still suffer when limited training data or unstable image quality is used. To overcome this problem, a Diffusion-Augmented Three-Dimensional Transformer is presented by incorporating a three-dimensional ResNet-18 backbone, an eight-layer transformer encoder, and diffusion-based augmentation. This design is aimed to enhance volumetric feature learning and increase the robustness to low-dose noise characteristics. Experiments were performed on the LUNA16 dataset based on Lung Image Database Consortium and Image Database Resource Initiative, which has 888 computed tomography scans and 1186 annotated nodules. Using ten-fold cross validation, the model was 95.2% sensitive, 91.7% precision, 94.1% recall, 92.9% F1 score, 0.971 area under curve and 0.946 competition performance metric. These results suggest that the proposed framework has a better lung disease screening performance than competing baselines. The model is thus appropriate for initial screening support of lung cancer, although additional multi-center validation is required for wider clinical implementation.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=252; abstract_english_function_words=68; abstract_english_share=0.2698; abstract_reads=english; language_check=metadata_listed